Add to Cart
Submersion Cooling System And Immersion Cooling System TurnKey Solution
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.
Working Diagram:
For Cryptocurrency mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Also, we have whole immersion cooling system clients, they can also offer the whole system proposal for you.
Features of dry cooler
High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan. |
We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar. |
Options
Coil design refrigerant: water, oil, glycol. | Multiple circuits. |
Sub-cooling circuits. | Stainless steel or aluminum casing. |
Coated aluminum or copper fins. | Explosion proof motor. |
Customized fin spacing. |
Technical parameter
Dry cooler D1 series parameter (fin space 2.1mm)
Type | D1-005- 1x350 | D1-006- 1x350 | D1-007- 1x350 | D1-009- 1x450 | D1-011- 1x450 | D1-013- 1x450 | D1-014- 1x500 | D1-017- 1x500 | D1-020- 1x500 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃ | △ | KW | 4.89 | 5.9 | 6.83 | 9.39 | 10.99 | 13.33 | 14.32 | 17.01 | 19.8 |
outlet | 40℃ | Y | |||||||||||||
20% Glycol | Inlet | 45℃ | △ | 4.72 | 5.69 | 6.69 | 8.9 | 10.61 | 13.05 | 13.91 | 16.11 | 19.29 | |||
outlet | 40℃ | Y | |||||||||||||
Medium | Water flow | M3/h | 0.85 | 1.03 | 1.2 | 1.63 | 1.91 | 2.3 | 2.5 | 3 | 3.5 | ||||
Pressure drop | kPa | 36 | 31 | 58 | 25 | 40 | 80 | 50 | 60 | 40 | |||||
Air flow | △ | M3/h | 2828 | 2712 | 2492 | 6199 | 5827 | 5225 | 8469 | 8168 | 7601 | ||||
Y | |||||||||||||||
Fan motor | Phase | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 140 | 140 | 140 | 540 | 540 | 540 | 830 | 830 | 830 | |||||
Y | |||||||||||||||
△ | A | 0.6 | 0.6 | 0.6 | 1.1 | 1.1 | 1.1 | 1.45 | 1.45 | 1.45 | |||||
Y | |||||||||||||||
Fan | No X φ | 1x1x350 | 1x1x350 | 1x1x350 | 1x1x450 | 1x1x450 | 1x1x450 | 1x1x500 | 1x1x500 | 1x1x500 | |||||
Sound pressure level | △ | dB(A) | 31 | 31 | 31 | 43 | 43 | 43 | 49 | 49 | 49 | ||||
Y | 10m | ||||||||||||||
Dimension | L | mm | 870 | 870 | 870 | 1020 | 1020 | 1020 | 1220 | 1220 | 1220 | ||||
W | mm | 525 | 525 | 525 | 625 | 625 | 625 | 825 | 825 | 825 | |||||
H | mm | 797 | 797 | 797 | 820 | 820 | 820 | 870 | 870 | 870 | |||||
A | mm | 690 | 690 | 690 | 840 | 840 | 840 | 1040 | 1040 | 1040 | |||||
B | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
C | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
D | mm | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Product weight(empty) | kg | 38 | 42 | 48 | 55 | 60 | 67 | 75 | 82 | 91 |
Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350
We can OEM design dry coolers.
Tell us the datas as following:
A. Required BC888·s inlet temperature?
B. Required BC888·s outlet temperature?
C. BC888 flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?
Packing and loading:
![]() | ![]() |
![]() | ![]() |
Reference:
For data center cooling | Country: Mongolia Application: match with precision air conditioner Cooling capacity: 17.6kW Cooling medium: 34% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application:data center cooling Cooling capacity: 763kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg |
![]() | ![]() | |
![]() | ![]() | |
For power plant | Country: Hongkong Application: power plant Cooling capacity: 363kW Cooling medium: water Supply power: 415V/3P/50Hz Fan brand: Chinese brand | Country: Russia Application: power plant. Cooling capacity: 180kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Chinese brand |
![]() | ![]() |