Power Plant Data Center Multiple Circuits Industrial Dry Cooler

Ask Latest Price
Video Channel
Brand Name :Shenglin
Model Number :D1 Series
Certification :CE and RoHs
Place of Origin :China
MOQ :1
Price :610~3002 USD/Unit
Payment Terms :T/T, Western Union, L/C
Supply Ability :75~100 units per month
Delivery Time :35~40 days
Packaging Details :Stretch film+ pallet for container loading
Tube material :Cu
Fin material :Al
Frame material :G.I and Al and SUS
Power supply :380V and 415V
Options :Hydraulic module is available
Options A :Sprinkler System we can design
Options B :Adiabatic system we can design
Fan brand :ZIEHL-ABEGG or ebm brand is available
Product Category :Industrial Dry Cooler
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Power Plant and Data Center Cooling Dry Cooling System Multiple Circuits Heat Exchanger Coil

Why many large data centers have already moved or are considering the move to immersion cooling?

1. Save floor space. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much floor space. Because no need rack system and no need air conditioner indoor.

2. Save power. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much power. For example, no need to install many air conditioners indoor, then no compressor power consumption. For example, the bitcoin miners no need air cooling fans. Thesewill save power around 18~25%.

3. Increase hardware lifepan. In immersion, machines operate in a 100% controlled environment with no dust, no temperature of humidity fluctuations, no impurities. This will extend the service life of the mining machine or server. This will also reduce machine maintainance fee.

4. Increase hashrate of the mining machine.

For immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.

Features

High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.
We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.

Options

Coil design refrigerant: water, oil, glycol. Multiple circuits.
Sub-cooling circuits. Stainless steel or aluminum casing.
Coated aluminum or copper fins. Explosion-proof motor.
Customized fin spacing.

Technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-005-

1x350

D1-006-

1x350

D1-007-

1x350

D1-009-

1x450

D1-011-

1x450

D1-013-

1x450

D1-014-

1x500

D1-017-

1x500

D1-020-

1x500

Capacity Water 35℃ outdoor temp. Inlet 45℃, KW 4.89 5.9 6.83 9.39 10.99 13.33 14.32 17.01 19.8
outlet 40℃ Y
20% Glycol Inlet 45℃ 4.72 5.69 6.69 8.9 10.61 13.05 13.91 16.11 19.29
outlet 40℃ Y
Medium Water flow M3/h 0.85 1.03 1.2 1.63 1.91 2.3 2.5 3 3.5
Pressure drop kPa 36 31 58 25 40 80 50 60 40
Air flow M3/h 2828 2712 2492 6199 5827 5225 8469 8168 7601
Y
Fan motor Phase 1 1 1 3 3 3 3 3 3
W 140 140 140 540 540 540 830 830 830
Y
A 0.6 0.6 0.6 1.1 1.1 1.1 1.45 1.45 1.45
Y
Fan No X φ 1x1x350 1x1x350 1x1x350 1x1x450 1x1x450 1x1x450 1x1x500 1x1x500 1x1x500
Sound pressure level dB(A) 31 31 31 43 43 43 49 49 49
Y 10m
Dimension L mm 870 870 870 1020 1020 1020 1220 1220 1220
W mm 525 525 525 625 625 625 825 825 825
H mm 797 797 797 820 820 820 870 870 870
A mm 690 690 690 840 840 840 1040 1040 1040
B mm -- -- -- -- -- -- -- -- --
C mm -- -- -- -- -- -- -- -- --
D mm 490 490 490 490 490 490 490 490 490
Inlet φ mm 3/4 3/4 3/4 1 1 1 1-1/4 1-1/4 1-1/4
Inlet φ mm 3/4 3/4 3/4 1 1 1 1-1/4 1-1/4 1-1/4
Product weight(empty) kg 38 42 48 55 60 67 75 82 91

Application:

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.

Reference:

Dry cooler case
Case 1: used in chemical plant.

Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h)

Power Plant Data Center Multiple Circuits Industrial Dry CoolerPower Plant Data Center Multiple Circuits Industrial Dry Cooler Power Plant Data Center Multiple Circuits Industrial Dry CoolerPower Plant Data Center Multiple Circuits Industrial Dry Cooler
Case 3: used in communication station as air conditioner outdoor unit in China.

Case 4: used in communication station as air conditioner outdoor unit

Power Plant Data Center Multiple Circuits Industrial Dry Cooler Power Plant Data Center Multiple Circuits Industrial Dry Cooler
For data center cooling Country: Mongolia
Application: match with precision air conditioner
Cooling capacity: 17.6kW
Cooling medium: 34% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application:data center cooling
Cooling capacity: 763kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
Power Plant Data Center Multiple Circuits Industrial Dry Cooler Power Plant Data Center Multiple Circuits Industrial Dry Cooler
For power plant Country: Hongkong
Application: power plant
Cooling capacity: 363kW
Cooling medium: water
Supply power: 415V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: power plant.
Cooling capacity: 180kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
Power Plant Data Center Multiple Circuits Industrial Dry Cooler Power Plant Data Center Multiple Circuits Industrial Dry Cooler

How to Oder your Own Type of Dry Cooler?

Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature
B. Required electrolyte​ outlet temperature
C. Electrolyte​ flow
D. Ambient temperature
E. Supply power(voltage-Hz-phase)
G. Additional requirements