Add to Cart
Rooftop Package Unit Roof Top Air Conditioner Central Air Conditioning Boats Rooftop Aircon HVAC Units
Rooftop HVAC units Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
Model:SL-WKX | 110 | 120 | 150 | 180 | 240 | ||||||
Cooling capacity1* | kw | 108.0 | 126.0 | 151.0 | 178.0 | 240.0 | |||||
Heating capacity2* | kw | 62.3 | 75.6 | 88.3 | 105.0 | 140.0 | |||||
Fresh air volume 3* | m3/h | 8000 | 11000 | 9500 | 12000 | 11500 | 15000 | 13500 | 18000 | 18000 | 24000 |
Static Pressure 3* | Pa | 300 | 350 | 350 | 350 | 350 | 400 | 350 | 400 | 400 | 450 |
Fan power 3* | kw | 3.0 | 4.0 | 4.0 | 4.0 | 4.0 | 7.5 | 5.5 | 11.0 | 11.0 | 15.0 |
Noise 4* | dB(A) | 66 | 67 | 68 | 70 | 70 | 71 | 72 | 73 | 73 | 75 |
Humidification5* | Kg/h | 40 | 40 | 50 | 50 | 66 | |||||
Power | - | 3N-380V-50Hz | |||||||||
Input power | kw | 39.3 | 40.3 | 44 | 44 | 53 | 56.8 | 68 | 73.7 | 88 | 92.3 |
Compressor 6* | Type | Hermetic Scroll | |||||||||
Number | 4 | 4 | 4 | 4 | 6 | ||||||
Refrigerant | Type | R22/R407C/R410A | |||||||||
Manner | External balance type thermal expansion value/Electronic expansion value | ||||||||||
Strainer | - | Initial effect G4(Middle effect F8/Nanocrystalline carbon filter) | |||||||||
Drain pip | - | DN40 | DN40 | DN40 | DN40 | DN50 | |||||
Overall dimensions | Length(mm) | 6000 | 6000 | 6000 | 6000 | 6800 | |||||
Width(mm) | 2300 | 2300 | 2300 | 2300 | 2300 | ||||||
Height(mm) | 2300 | 2300 | 2300 | 2300 | 2800 | ||||||
Unit weight | kg | 1420 | 1450 | 1680 | 1760 | 1750 | 1820 | 2450 | 2560 | 3150 | 3210 |
1. Cooling conditions: indoor dry/wet bulb: 35/28℃, outdoor dry/wet bulb: 27/19℃
2. Heating conditions: indoor dry bulb/wet bulb: 0/-2.9°C; outdoor dry bulb/wet bulb: 20/15°C;
3. The air volume and static pressure specifications in the table are standard specifications and can be designed.
4. The noise is measured at 1.2m and 2m from the front of the unit when the standard air volume is used for cooling;
5. Heaters, humidifiers, hot and cold water coils are optional parts, and the specific form can be configured according to customer site requirements;
6. Frequency conversion compressor system can be used to achieve more precise capacity control;
7. The fresh air unit can only handle fresh air, and indoor temperature control and main load-bearing must be handled by standard air-conditioning equipment.
Application:
Such as hotel, office building, centralized air conditioning requirements of buildings, shopping malls, dance halls, theaters, hospitals, hydropower engineering, computer room and industrial and mining enterprises and other occasions.
Reference:
Country: Turkey Application:distributor Type: heat pump type Cooling capacity: 108.9KW; Heating capacity: 113KW; 380V-3Ph-50hz R410a ESP: 350 Pa; 19940 m3/h 25% fresh air; | Country: Nigeria Application: Pharmaceutical Factory Type: heat pump type Cooling capacity: 36.2kW Heating capacity: 82kW Refrigerant: R407C Compressor: Sanyo | Country: Jordan Application: Textile Factory Type: heat pipe heat recovery type Cooling capacity: 368kW Heating capacity: 359kW Refrigerant: R410A Compressor: Copeland With heat recovery coil |
![]() | ![]() | ![]() |
Country:UAE Application:offshore Drilling Platform Cooling capacity: 80kw Supply air volume: 4000×2 m3/h Condensing fan: 12000m3/h Refrigerant: R407C Power supply:430V-3Ph-60Hz Evaporator & condenser type: copper tube epoxy aluminum fin | Country:Australia Application:hall Cooling capacity: 128kw Heating capacity: 135kw Capacity regulator: 0,25,50,75,100 Power supply: 415V/3PH/50hz Refrigerant:R410A | Country:China Application: Amusement park Cooling capacity: 180kw Heating capacity: 192.5kw Supply air volume: 32000m3/h ESP: 550pa Power supply: 380V/3PH/50hz Refrigerant:R22 |
![]() | ![]() | ![]() |