Add to Cart
High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units
Description:
1. Cooling capacity: 120kw to 250kw, a variety of choices.
2. High external pressure.
3. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.
Feature 1
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
The unit has its cold and heat source and is air-cooled direct evaporative air-conditioning equipment. The entire air-conditioning system is only composed of an outdoor host and an indoor air duct. No cooling water and chilled water systems are required. It is easy to install and use, suitable for water-scarce areas.
The unit is designed for open-air installation on the roof or outdoor open space. It has the performance of anti-sun exposure, anti-corrosion, anti-torrential rain, etc., which can save the cost of air conditioning machine room and civil engineering.
Both the evaporator and condenser adopt enhanced heat transfer technology, which is highly efficient and energy-saving; the main parts are all imported high-quality products with excellent performance.
The unit has various air treatment functions, which can easily realize various functions such as air purification, dehumidification, humidification, refrigeration, and heating.
Feature 2
A. Efficient Operation | Our packaged rooftop units cut energy costs significantly while meeting all applicable code compliance requirements. |
B. Simplified Installation | Embedded Smart Equipment and thoughtful design features make installation, start-up and commissioning faster and more accurate. |
C. Integrated Flexibility | Field-installed accessories and an array of heating and air conditioning options help meet the needs of more applications. |
Model:SL-WKR-()-HR | 120 | 150 | 180 | 200 | 250 | ||
Cooling capacity1* | kW | 126.0(46.9) | 151.0(57.8) | 178.0(65.5) | 203.0(74.3) | 249.2(90.9) | |
Heating capacity2* | kW | 138.6(51.6) | 162.0(63.5) | 190.3(72.0) | 223.3(81.7) | 271.9(96.4) | |
Supply fan 3* | Type | - | Centrifugal | ||||
Air volume | m³/h | 12000 | 15000 | 17000 | 19500 | 24000 | |
Static Pressure | Pa | 400 | 400 | 400 | 400 | 450 | |
Motor power | kW | 5.5 | 5.5 | 7.5 | 7.5 | 11.0 | |
Exhaust fan 3* | Type | - | Centrifugal | ||||
Air volume | m³/h | 12000 | 15000 | 17000 | 19500 | 24000 | |
Static Pressure | Pa | 400 | 400 | 400 | 400 | 450 | |
Motor power | kW | 5.5 | 5.5 | 7.5 | 7.5 | 11.0 | |
Supply power | - | 3N-380V-50Hz | |||||
Input power 3* | kW | 35.3 | 40.6 | 47.2 | 53.2 | 65.4 | |
Heat recovery wheel | Type | - | Full heat recovery wheel | ||||
Wheel heat recovery efficiency | % | 69.2 | 65.0 | 68.2 | 68.1 | 65.0 | |
Temperature recovery efficiency | % | 71.5 | 70.5 | 70.5 | 70.4 | 67.4 | |
Compressor 4* | Type 3* | - | Hermetic Scroll | ||||
Power | kW | 5.7*4 | 6.8*4 | 7.5*4 | 9*4 | 10.1*4 | |
Refrigerant | Type | - | R22/R407C/R410A | ||||
Manner | - | External balance type thermal expansion value/Electronic expansion value | |||||
humidifier 5* | Type | - | Wet film | ||||
Humidification | kg/h | 50.0 | 70.0 | 80.0 | 100.0 | 120.0 | |
Noise 6* | dB(A) | 67 | 69 | 69 | 75 | 78 | |
Filter | - | Initial effect G4(Middle effect F8/Nanocrystalline carbon filter) | |||||
Drain pipe | - | DN32 | DN32 | DN32 | DN40 | DN40 | |
Overall dimensions | Length(mm) | 5800 | 5800 | 5800 | 5800 | 5800 | |
Width(mm) | 2550 | 2550 | 2550 | 2550 | 2550 | ||
Height(mm) | 2745 | 2745 | 2745 | 2745 | 2745 | ||
Unit weight | kg | 3500 | 3810 | 4130 | 4390 | 4560 |
1. Cooling condition: Indoor dry bulb/wet bulb: 35/24℃,Outdoor dry bulb/wet bulb: 27/19℃
2. Heating condition:Indoor dry bulb/wet bulb: 7/6℃;outdoor dry bulb/wet bulb:20/13.8℃;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. The inverter compressor system can be used to achieve more precise capacity control;
5. Heaters, humidifiers, hot and cold water coils are optional parts, and specific forms can be configured according to customer site requirements;
6. The noise is measured at a height of 1.2m and 2m directly in front of the unit when cooling under standard air volume;
7. The unit adopts a runner heat recovery device, and can be equipped with plate heat recovery and heat pipe heat recovery devices according to customer site requirements.
8. The fresh air unit is limited to processing fresh air, indoor temperature control and main load bearing must be handled by standard air conditioning equipment.
Reference:
Application: Rolling bearing manufacturer Type: wheel heat recovery type Cooling capacity: 95kw Condensation and heating capacity: 55kw Supply air volume: 19000m3/h Exhaust air volume: 19000m3/h | Application:Ferry waiting hall Type: heat pump type Cooling capacity:182.5kw Supply air volume: 22000m3/h | Application: Cool Storehouse Type: constant temperature and constant humidity unit Cooling capacity: 22kW Electric heating capacity: 82kW Humidifying capacity: 6kg/h Supply air: 4500 m3/h |
![]() | ![]() | ![]() |