Add to Cart
Floor Standing Adiabatic Cooling Pad Systems Hybrid Dry Cooler For Process Cooling
Adiabatic dry coolers combine the best of evaporative and dry cooling to optimize energy and water savings. Users can reduce peak energy use by 44% vs. traditional air-cooled products or reduce water use by 90% vs. traditional evaporative products. For all of your commercial and industrial refrigeration application needs dry cooler, and fluid cooler models are available.
Principle:
Features of normal dry cooler
High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan. |
We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar. |
Options
Coil design refrigerant: water, oil, glycol. | Multiple circuits. |
Sub-cooling circuits. | Stainless steel or aluminum casing. |
Coated aluminum or copper fins. | Explosion proof motor. |
Customized fin spacing. |
Technical parameter
Dry cooler D1 series parameter(fin space 2.1mm)
Type | D1-005- 1x350 | D1-006- 1x350 | D1-007- 1x350 | D1-009- 1x450 | D1-011- 1x450 | D1-013- 1x450 | D1-014- 1x500 | D1-017- 1x500 | D1-020- 1x500 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | △ | KW | 4.89 | 5.9 | 6.83 | 9.39 | 10.99 | 13.33 | 14.32 | 17.01 | 19.8 |
outlet | 40℃ | Y | |||||||||||||
20% Glycol | Inlet | 45℃ | △ | 4.72 | 5.69 | 6.69 | 8.9 | 10.61 | 13.05 | 13.91 | 16.11 | 19.29 | |||
outlet | 40℃ | Y | |||||||||||||
Medium | Water flow | M3/h | 0.85 | 1.03 | 1.2 | 1.63 | 1.91 | 2.3 | 2.5 | 3 | 3.5 | ||||
Pressure drop | kPa | 36 | 31 | 58 | 25 | 40 | 80 | 50 | 60 | 40 | |||||
Air flow | △ | M3/h | 2828 | 2712 | 2492 | 6199 | 5827 | 5225 | 8469 | 8168 | 7601 | ||||
Y | |||||||||||||||
Fan motor | Phase | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 140 | 140 | 140 | 540 | 540 | 540 | 830 | 830 | 830 | |||||
Y | |||||||||||||||
△ | A | 0.6 | 0.6 | 0.6 | 1.1 | 1.1 | 1.1 | 1.45 | 1.45 | 1.45 | |||||
Y | |||||||||||||||
Fan | No X φ | 1x1x350 | 1x1x350 | 1x1x350 | 1x1x450 | 1x1x450 | 1x1x450 | 1x1x500 | 1x1x500 | 1x1x500 | |||||
Sound pressure level | △ | dB(A) | 31 | 31 | 31 | 43 | 43 | 43 | 49 | 49 | 49 | ||||
Y | 10m | ||||||||||||||
Dimension | L | mm | 870 | 870 | 870 | 1020 | 1020 | 1020 | 1220 | 1220 | 1220 | ||||
W | mm | 525 | 525 | 525 | 625 | 625 | 625 | 825 | 825 | 825 | |||||
H | mm | 797 | 797 | 797 | 820 | 820 | 820 | 870 | 870 | 870 | |||||
A | mm | 690 | 690 | 690 | 840 | 840 | 840 | 1040 | 1040 | 1040 | |||||
B | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
C | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
D | mm | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Product weight(empty) | kg | 38 | 42 | 48 | 55 | 60 | 67 | 75 | 82 | 91 |
Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
How to design a dry cooler?
Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte outlet temperature?
C. Electrolyte flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?
Optional features
• EC variable speed fan motor, to save great energy
• ZAplus/AxiTop for greater volume flow and extreme silence
• Adiabatic system significantly reduces energy consumption in summer
• Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area
• Fluid dry cooler
• Clean stainless steel tube and aluminum fin coil for cooling deionized water.
Packing:
![]() | ![]() |
![]() | ![]() |
Reference:
Dry cooler case | |
Case 1: used in chemical plant. | Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h)
|
![]() ![]() | ![]() ![]() |
Case 3: used in communication station as air conditioner outdoor unit in China. | Case 4: used in communication station as air conditioner outdoor unit
|
![]() | ![]() |