Closed Loop Flat Type Copper Tube Aluminum Fin Dry Cooler Systems
How is closed-loop dry cooling system?
The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and are easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.
The best location for the fluid cooler is usually on the roof because it requires free clear air to work efficiently.
However, the coolant must also have some kind of glycol to prevent freezing if your location has a designed dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations increasingly begin to reduce the rate of heat transfer.
The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100F in the summer and your equipment requires 90F coolant, while the system can only supply around 105F to 110F coolant to the load. In this case, you would need supplemental cooling to get the coolant temperatures down to 90 F.
Dry fluid cooler features:
Air discharge direction | ![]() |
Performance ranges | Cooling capacity: from 5 to 649 kw Air volume: from 2828 to 263503 m3/h Sound pressure level: from 31 to 69 dB A(10m) Dry coolers:customized on demand |
High efficiency heat exchanger | Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan | Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
Testing | Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options | Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing.
|
Dry fluid cooler technical parameter
Dry cooler D1 series parameter(fin space 2.1mm)
Type | D1-166- 4x630 | D1-211- 6x630 | D1-247- 6x630 | D1-286- 8x630 | D1-334- 8x630 | D1-360- 10x630 | D1-415- 10x630 | D1-502- 12x630 | D1-565- 14x630 | D1-649- 16x630 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | △ | KW | 165.92 | 211.36 | 247.3 | 286.15 | 334.49 | 359.72 | 415.31 | 502.25 | 565.18 | 649.48 |
outlet | 40℃ | Y | 134.59 | 176.00 | 200.45 | 238.3 | 270.889 | 298.57 | 335.225 | 405.20 | 459.3 | 527.59 | ||||
20% Glycol | Inlet | 45℃ | △ | 161.32 | 205.08 | 240.46 | 280.05 | 327.72 | 351.3 | 406.48 | 493.40 | 554.21 | 638.44 | |||
outlet | 40℃ | Y | 130.96 | 170.87 | 195.07 | 233.18 | 265.64 | 291.81 | 328.48 | 398.45 | 450.87 | 519.13 | ||||
Medium | Water flow | M3/h | 29.00 | 37 | 43 | 50 | 58 | 63 | 72 | 88 | 98 | 113 | ||||
Pressure drop | kPa | 50 | 70 | 47 | 97 | 95 | 92 | 70 | 97 | 96 | 95 | |||||
Air flow | △ | M3/h | 67455 | 109723 | 101185 | 146293 | 134908 | 179502 | 164442 | 197326 | 230584 | 263503 | ||||
Y | 51265 | 83661 | 76900 | 111544 | 102528 | 136437 | 124680 | 149612 | 174710 | 199665 | ||||||
Fan motor | Phase | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 1100 | 16500 | 16500 | 22000 | 22000 | 27500 | 27500 | 33000 | 38500 | 44000 | |||||
Y | 700 | 10500 | 10500 | 14000 | 14000 | 17500 | 17500 | 21000 | 24500 | 28000 | ||||||
△ | A | 20.4 | 30.6 | 30.6 | 40.8 | 40.8 | 51.00 | 51.00 | 61.20 | 71.40 | 81.60 | |||||
Y | 12.00 | 18.00 | 18.00 | 24.00 | 24.00 | 30.00 | 30.00 | 36.00 | 42.00 | 48.00 | ||||||
Fan | No X φ | 2X2 X630 | 2x3 x630 | 2x3 x630 | 2x4 x630 | 2x4 x630 | 2x5 x630 | 2x5 x630 | 2x6 x630 | 2x7 x630 | 2x8 x630 | |||||
Sound pressure level | △ | dB(A) | 64 | 66 | 66 | 67 | 67 | 68 | 68 | 68 | 69 | 69 | ||||
Y | 10m | 57 | 59 | 59 | 60 | 60 | 61 | 61 | 61 | 62 | 62 | |||||
Dimension | L | mm | 2930 | 4230 | 4230 | 5530 | 5530 | 6830 | 6830 | 8130 | 9430 | 10730 | ||||
W | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | |||||
H | mm | 1070 | 1070 | 1070 | 1070 | 1070 | 1120 | 1120 | 1120 | 1120 | 1120 | |||||
A | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
B | mm | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | |||||
C | mm | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | |||||
D | mm | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | |||||
Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 | 2X DN125 | 2X DN125 | |||||
Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 | 2X DN125 | 2X DN125 | |||||
Product weight(empty) | kg | 658 | 689 | 760 | 1105 | 1270 | 1320 | 1420 | 1584 | 1848 | 2112 |
Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
How to design a dry cooler?
Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte outlet temperature?
C. Electrolyte flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?
Optional features:
• EC variable speed fan motor, to save great energy
• ZAplus/AxiTop for greater volume flow and extreme silence
• Adiabatic system significantly reduces energy consumption in summer
• Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area
• Fluid dry cooler
• Clean stainless steel tube and aluminum fin coil for cooling deionized water.
Why Choose us
Professional system integration Customized size Thermodynamic calculations Authoritative seismic design Integrated wet curtain celdek7090 | Frame: Galvanized sheet sprayed (rai 7035) Hot dip galvanized sheet Stainless steel plate Galvanized sheet | AC-EC fan: Protection grade ip55 Low energy consumption Inverter control High temperature resistant fan Explosion-proof fan | Various diameter fans are available: 800, 1~14 psc 910, 1~18 psc 1250, 1~8 psc 1800, 1~7 psc |
Pipe: Copper Copper nickel alloy Stainless steel Titanium | Fin: Epoxy coating Aluminum Copper: Tinned copper foil Blygold coating Stainless steel Titanium | Overhaul and cleaning: Easy to clean Optional access door or hinged fan panel Fin form for easy cleaning Robust material with high mechanical strength Easy to maintain | Different connection options: Flange connection Threaded connection Welding |
Reference:
For solar industry | Country: China Application :cooling of solar heating system when it is overheated Cooling capacity: 463, 933 and 1475kW Cooling medium: 50% propylene glycol water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg Altitude:4200m | Country: UAE Application: solar thermal system Cooling capacity: 21kw Cooling medium: water Supply power: 230V/1P/50Hz Fan brand: Chinese brand | Country: Korea Application: solar system overheated Cooling capacity: 32kW Cooling medium: 30% ethylene glycol water Supply power: 230V/1P/60Hz Fan brand: Chinese brand |
![]() | ![]() | ![]() | |
For plastic industry | Country: Algeria Application: cooling water from injection molding machine Cooling capacity: 694kW Cooling medium: water Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Armenia Application: for plastic caps of beverages factory Cooling capacity:70kW Cooling medium: 34% ethylene glycol Supply power: 380V/3P/50Hz Fan brand: Chinese brand | Country: Russia Application: bathtub factory Inlet/outlet air temperature:40℃/66℃ Inlet/outlet water temperature:85℃/50℃ Air volume:7986m3/h Cooling medium:water Supply power: 380V/3P/50Hz Fan brand: Chinese brand |
![]() | ![]() | ![]() | |
Instead of cooling tower | Country: Argentina Application: for equipment cooling, to match chiller. Cooling capacity: 245kW Cooling medium: water Supply power:380V/3P/50Hz Fan brand: Chinese brand | Country: Peru Application: instead of cooling tower, to match chiller. Cooling capacity: 360kW Cooling medium: water Supply power:440V/3P/60Hz Fan brand: Chinese brand With wet curtain, with water pump and water tank | Country: Mauritius Application: supermarket and will match chiller use. Heat transfer capacity: 502kW Cooling medium: water Inlet air temp.: 32℃ Inlet medium temp.: 42℃ Outlet medium temp.: 37℃ Medium volume: 88m3/h Material: copper tube aluminum fin and galvanized steel frame, RAL9010 powder coating. Supply power: 380V/3P/50Hz Fan brand: Chinese brand, air volume: 20228m3/h |
![]() | ![]() | ![]() |
For data center cooling | Country: Mongolia Application: match with precision air conditioner Cooling capacity: 17.6kW Cooling medium: 34% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application:data center cooling Cooling capacity: 763kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg |
![]() | ![]() | |
Factory cooling | Country: Russia Application: ore yard cooling Cooling capacity: 493kW Cooling medium: 20% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: China Application: plant cooling Cooling capacity: 52kW Cooling medium: 30% ethylene glycol Supply power: 380V/3P/50Hz Fan brand: Chinese brand |
![]() | ![]() | |
For power plant | Country: Hongkong Application: power plant Cooling capacity: 363kW Cooling medium: water Supply power: 415V/3P/50Hz Fan brand: Chinese brand | Country: Russia Application: power plant. Cooling capacity: 180kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Chinese brand |
![]() | ![]() |
Other application | Country: Singapore Application: match with fruit and vegerable freezer Cooling capacity: 14.6kw, 17kw and 29.37kw Cooling medium: 20% ethylene glycol Supply power: 230V/1P/50Hz Fan brand: Ziehl-Abegg | Country: Singapore Application: wastewater treatment factory, cooling water Cooling capacity: 429kW Cooling medium: water Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application: industrial cooling Cooling capacity: 153kW Cooling medium: 20% glycol Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg |
![]() | ![]() | ![]() |