
Add to Cart
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.
What's two-phase liquid cooling?
The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.
For bitcoin mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Also, we have whole immersion cooling system partner in USA and European, they can also offer the whole system proposal for you.
Features of adiabatic dry coolers
1. Material options:
A. Heavy-gauge hot-dip galvanized steel is used for unit steel panels and structural elements featuring a zinc aluminium coating.
2. Heat transfer media:
A. The dry cooler is constructed of staggered and seamless copper tubes (15,9 or 12,7 diameter) with aluminium, rippled and corrugated fins (0,14 or 0,17 thickness).
B. 2.5 mm fin spacing for optimal air turbulence
C. Thick and seamless copper headers and threaded steel connections
D. Pressure tested at 30 bar
E. Try our options for aggressive environments: special pre-coated anti-corrosion aluminium fins or copper fins (0,2 mm thickness).
3. Air movement system:
A. Axial fan with exceptionally compact direct drive short integrated motor and fan guard.
B. The fan features an impeller and motor and is balanced as a complete unit using dynamic single plane balancing. Balance grade is G6.3.
C. Fan and motor totally maintenance free.
D. Bearings seals and motor encapsulation for long service life.
Our USA partner can offer the cryptocurrency miner cooling system solution, like this way:
Technical parameter
Dry cooler D1 series parameter (fin space 2.1mm)
Type | D1-005- 1x350 | D1-006- 1x350 | D1-007- 1x350 | D1-009- 1x450 | D1-011- 1x450 | D1-013- 1x450 | D1-014- 1x500 | D1-017- 1x500 | D1-020- 1x500 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃ | △ | KW | 4.89 | 5.9 | 6.83 | 9.39 | 10.99 | 13.33 | 14.32 | 17.01 | 19.8 |
outlet | 40℃ | Y | |||||||||||||
20% Glycol | Inlet | 45℃ | △ | 4.72 | 5.69 | 6.69 | 8.9 | 10.61 | 13.05 | 13.91 | 16.11 | 19.29 | |||
outlet | 40℃ | Y | |||||||||||||
Medium | Water flow | M3/h | 0.85 | 1.03 | 1.2 | 1.63 | 1.91 | 2.3 | 2.5 | 3 | 3.5 | ||||
Pressure drop | kPa | 36 | 31 | 58 | 25 | 40 | 80 | 50 | 60 | 40 | |||||
Air flow | △ | M3/h | 2828 | 2712 | 2492 | 6199 | 5827 | 5225 | 8469 | 8168 | 7601 | ||||
Y | |||||||||||||||
Fan motor | Phase | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 140 | 140 | 140 | 540 | 540 | 540 | 830 | 830 | 830 | |||||
Y | |||||||||||||||
△ | A | 0.6 | 0.6 | 0.6 | 1.1 | 1.1 | 1.1 | 1.45 | 1.45 | 1.45 | |||||
Y | |||||||||||||||
Fan | No X φ | 1x1x350 | 1x1x350 | 1x1x350 | 1x1x450 | 1x1x450 | 1x1x450 | 1x1x500 | 1x1x500 | 1x1x500 | |||||
Sound pressure level | △ | dB(A) | 31 | 31 | 31 | 43 | 43 | 43 | 49 | 49 | 49 | ||||
Y | 10m | ||||||||||||||
Dimension | L | mm | 870 | 870 | 870 | 1020 | 1020 | 1020 | 1220 | 1220 | 1220 | ||||
W | mm | 525 | 525 | 525 | 625 | 625 | 625 | 825 | 825 | 825 | |||||
H | mm | 797 | 797 | 797 | 820 | 820 | 820 | 870 | 870 | 870 | |||||
A | mm | 690 | 690 | 690 | 840 | 840 | 840 | 1040 | 1040 | 1040 | |||||
B | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
C | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
D | mm | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Product weight(empty) | kg | 38 | 42 | 48 | 55 | 60 | 67 | 75 | 82 | 91 |
Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350