
Add to Cart
V-Type And Flat Type Dry Cooler Air Cooled Condenser for Data Centre Immersion Cooling System
Features
Why choose us:
Points of Shenglin dry cooler:
Professional system integration: Customized size Thermodynamic calculations Authoritative seismic design Integrated wet curtain celdek7090 | Frame: Galvanized sheet sprayed (RAI 7035) Hot dip galvanized sheet Stainless steel plate Galvanized sheet | AC-EC fan: Protection grade ip55 Low energy consumption Inverter control High temperature resistant fan Explosion-proof fan | Various diameter fans are available: 800, 1~14 psc 910, 1~18 psc 1250, 1~8 psc 1800, 1~7 psc |
Pipe: Copper Copper nickel alloy Stainless steel Titanium | Fin: Epoxy coating Aluminum Copper: Tinned copper foil Blygold coating Stainless steel Titanium | Overhaul and cleaning: Easy to clean Optional access door or hinged fan panel Fin form for easy cleaning Robust material with high mechanical strength Easy to maintain | Different connection options: Flange connection Threaded connection Welding |
Technical Paraments
Flat series — Double rows fans
H*FD*91 | Fan Dim mm | * | H*FD491 | H*FD691 | H*FD89 | H*FD1091 | H*FD1291 | H*FD1491 | H*FD1691 | H*FD1891 |
Rated Capacities (kW) Heat Exchange Surface (㎡) | ||||||||||
Fluid Coolers | 910 | D | 237kW-1632kW 454㎡-4903㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||
Freon Condensers | 910 | F | 285kW-1632kW 454㎡-4903㎡ (R404A/Ta35℃/Tk50℃) | |||||||
Ammonia Condensers | 910 | A | 151kW-1709kW 263㎡-5696㎡ (NH3/Ta35℃/Tk50℃) | |||||||
Gas Coolers | 910 | G | 156kW-1929kW 358㎡-3859㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃) | |||||||
Oil Coolers | 910 | O | 174kW-2212kW 454㎡-4903㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||
Fan Model | 910 | EC | W3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW) | |||||||
910 | AC | W6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW) | ||||||||
No of Fans | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | ||
Overall Dimensions | 910 | Lenth-1 | 3480 | 4980 | 6480 | 7980 | 9480 | 10980 | 12480 | 13980 |
Lenth-2 | 4080 | 5880 | 7680 | 9480 | 11280 | 13080 | 14880 | 16680 | ||
Width | 2265 | |||||||||
Height | 1740 (Including 800Leg) |
Reference:
For data center cooling | Country: Mongolia Application: match with precision air conditioner Cooling capacity: 17.6kW Cooling medium: 34% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application:data center cooling Cooling capacity: 763kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg |
![]() | ![]() | |
For power plant | Country: Hongkong Application: power plant Cooling capacity: 363kW Cooling medium: water Supply power: 415V/3P/50Hz Fan brand: Chinese brand | Country: Russia Application: power plant. Cooling capacity: 180kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Chinese brand |
![]() | ![]() |
Introduction of two-phase liquid cooling:
The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.