Add to Cart
Data Center Adiabatic Dry Air Cooler Dry Chiller Ethylene Glycol Cooler
Features of dry cooler
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
The unit has its cold and heat source and is air-cooled direct evaporative air-conditioning equipment. The entire air-conditioning system is only composed of an outdoor host and an indoor air duct. No cooling water and chilled water systems are required. It is easy to install and use, suitable for water-scarce areas.
The unit is designed for open-air installation on the roof or outdoor open space. It has the performance of anti-sun exposure, anti-corrosion, anti-torrential rain, etc., which can save the cost of air conditioning machine room and civil engineering.
Both the evaporator and condenser adopt enhanced heat transfer technology, which is highly efficient and energy-saving; the main parts are all imported high-quality products with excellent performance.
The unit has various air treatment functions, which can easily realize various functions such as air purification, dehumidification, humidification, refrigeration, and heating.
Structure
Panels and frame | Made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents. |
Coil | Direct expansion coils with condensate drain tray. |
Hermetic compressor | High-efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber . |
Vibration damper | Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise. |
Centrifugal fan | Forward curve centrifugal fans for air treatment section and axial fans for condensation section. Front, side, and underside air discharge of the treatment unit. High external pressure, long air supply distance. |
Electric panel | The electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay, and other necessary protection devices for the main components. |
Easy operation line controller | Cooling/Heating/Auto. Error indication. Timing on/off. |
Options
Coil design refrigerant: water, oil, glycol. | Multiple circuits. |
Sub-cooling circuits. | Stainless steel or aluminum casing. |
Coated aluminum or copper fins. | Explosion proof motor. |
Customized fin spacing. |
Technical parameter
Dry cooler D2 series parameter(fin space 2.1mm)
Type | D2-148- 4x630 | D2-166- 4x630 | D2-175- 4x630 | D2-228- 6x630 | D2-250- 6x630 | D2-276- 6x630 | D2-310- 8x630 | D2-343- 8x630 | D2-364- 8x630 | D2-392- 10x630 | |||
Capacity | Water | KW | 147.99 | 165.85 | 175.21 | 227.85 | 250.42 | 276.53 | 309.85 | 342.73 | 364.07 | 391.99 | |
20% Et. Glycol | KW | 142.42 | 161.57 | 170.91 | 219.09 | 244.69 | 270.22 | 301.18 | 333.55 | 354.64 | 383.3 | ||
Air flow | M3/h | 76459 | 74341 | 72134 | 114686 | 111511 | 108188 | 152911 | 148675 | 144255 | 191136 | ||
Fan | No. X φ | 2x2x630 | 2x2x630 | 2x2x630 | 2x3x630 | 2x3x630 | 2x3x630 | 2x4x630 | 2x4x630 | 2x4x630 | 2x5x630 | ||
Fan motor | A | 20.4 | 20.4 | 20.4 | 30.6 | 30.6 | 30.6 | 40.8 | 40.8 | 40.8 | 51 | ||
400/3N/50HZ | |||||||||||||
Sound pressure level | dB(A)10m | 64 | 64 | 64 | 66 | 66 | 66 | 67 | 67 | 67 | 68 | ||
Dimension | L | mm | 2186 | 2186 | 2186 | 3250 | 3250 | 3250 | 4250 | 4250 | 4250 | 5250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
L3 | mm | 1963 | 1963 | 1963 | 2963 | 2963 | 2963 | 3963 | 3963 | 3963 | 4963 | ||
Connections inlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Connections onlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Product weight(empty) | kg | 769 | 811 | 853 | 1134 | 1197 | 1261 | 1498 | 1589 | 1673 | 1864 |
Shenglin dry cooler selection software example:
Some reference:
![]() | ![]() |
Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 1270kW Cooling medium: BC-888 Supply power: 415V/3P/60Hz Fan brand: Ziehl-Abegg
| Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 171kW Cooling medium: bitcoin fluid Supply power: 415V/3P/60Hz Fan brand: Chinese brand
|