Closed-loop Dry Systems Table Type Copper Tube Aluminum Fin Fluid Cooler
What is closed-loop dry cooling system?
The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and it is easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.
The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100 F in the summer and your equipment requires 90 F coolant; at best the system can only supply around 105 to 110 F coolant to the load. In this case you would need supplemental cooling to get the coolant temperatures down to 90 F.
The closed-loop dry cooling system also requires free clear air to work efficiently. This means that the fluid cooler must be placed in a location that is not affected by the prevailing winds, not too close to a building that will allow the warm exhaust air from the fluid cooler to be recirculated back to the fluid cooler, and finally not in a location that has heavy concentrations of dust, dirt, leaves, seeds, etc.
Many times the best location for the fluid cooler is on the roof. Since the fluid cooler is located outside the coolant must also have a concentration of some type of glycol to prevent freezing if your location has a design dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations as they increase begin to reduce the rate of heat transfer. For example, if you need 50% ethylene glycol concentration with water the heat exchanger equipment and the flow/pressure of the coolant will need to increase to adjust for the glycol concentration. Larger fluid coolers and pumps will increase the cost of the system over those with lesser concentrations of Glycol/water. This cannot be prevented in colder climates.
Dry fluid cooler features:
Air discharge direction | ![]() |
Performance ranges | Cooling capacity: from 5 to 649 kw Air volume: from 2828 to 263503 m3/h Sound pressure level: from 31 to 69 dB A(10m) Dry coolers:customized on demand |
High efficiency heat exchanger | Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan | Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
Testing | Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options | Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing.
|
Dry fluid cooler technical parameter
Dry cooler D1 series parameter(fin space 2.1mm)
Type | D1-166- 4x630 | D1-211- 6x630 | D1-247- 6x630 | D1-286- 8x630 | D1-334- 8x630 | D1-360- 10x630 | D1-415- 10x630 | D1-502- 12x630 | D1-565- 14x630 | D1-649- 16x630 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | △ | KW | 165.92 | 211.36 | 247.3 | 286.15 | 334.49 | 359.72 | 415.31 | 502.25 | 565.18 | 649.48 |
outlet | 40℃ | Y | 134.59 | 176.00 | 200.45 | 238.3 | 270.889 | 298.57 | 335.225 | 405.20 | 459.3 | 527.59 | ||||
20% Glycol | Inlet | 45℃ | △ | 161.32 | 205.08 | 240.46 | 280.05 | 327.72 | 351.3 | 406.48 | 493.40 | 554.21 | 638.44 | |||
outlet | 40℃ | Y | 130.96 | 170.87 | 195.07 | 233.18 | 265.64 | 291.81 | 328.48 | 398.45 | 450.87 | 519.13 | ||||
Medium | Water flow | M3/h | 29.00 | 37 | 43 | 50 | 58 | 63 | 72 | 88 | 98 | 113 | ||||
Pressure drop | kPa | 50 | 70 | 47 | 97 | 95 | 92 | 70 | 97 | 96 | 95 | |||||
Air flow | △ | M3/h | 67455 | 109723 | 101185 | 146293 | 134908 | 179502 | 164442 | 197326 | 230584 | 263503 | ||||
Y | 51265 | 83661 | 76900 | 111544 | 102528 | 136437 | 124680 | 149612 | 174710 | 199665 | ||||||
Fan motor | Phase | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 1100 | 16500 | 16500 | 22000 | 22000 | 27500 | 27500 | 33000 | 38500 | 44000 | |||||
Y | 700 | 10500 | 10500 | 14000 | 14000 | 17500 | 17500 | 21000 | 24500 | 28000 | ||||||
△ | A | 20.4 | 30.6 | 30.6 | 40.8 | 40.8 | 51.00 | 51.00 | 61.20 | 71.40 | 81.60 | |||||
Y | 12.00 | 18.00 | 18.00 | 24.00 | 24.00 | 30.00 | 30.00 | 36.00 | 42.00 | 48.00 | ||||||
Fan | No X φ | 2X2 X630 | 2x3 x630 | 2x3 x630 | 2x4 x630 | 2x4 x630 | 2x5 x630 | 2x5 x630 | 2x6 x630 | 2x7 x630 | 2x8 x630 | |||||
Sound pressure level | △ | dB(A) | 64 | 66 | 66 | 67 | 67 | 68 | 68 | 68 | 69 | 69 | ||||
Y | 10m | 57 | 59 | 59 | 60 | 60 | 61 | 61 | 61 | 62 | 62 | |||||
Dimension | L | mm | 2930 | 4230 | 4230 | 5530 | 5530 | 6830 | 6830 | 8130 | 9430 | 10730 | ||||
W | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | |||||
H | mm | 1070 | 1070 | 1070 | 1070 | 1070 | 1120 | 1120 | 1120 | 1120 | 1120 | |||||
A | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
B | mm | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | |||||
C | mm | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | |||||
D | mm | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | |||||
Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 | 2X DN125 | 2X DN125 | |||||
Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 | 2X DN125 | 2X DN125 | |||||
Product weight(empty) | kg | 658 | 689 | 760 | 1105 | 1270 | 1320 | 1420 | 1584 | 1848 | 2112 |
Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
Shenglin dry fluid cooler selection software example: