PCR Laboratory Close Control AHU Clean Room Air Conditioner

Ask Latest Price
Brand Name :Shenglin
Model Number :Non standard
Certification :CE
Place of Origin :China
MOQ :1
Price :5000~10015USD/unit
Payment Terms :T/T, Western Union
Supply Ability :100 Units Per Month
Delivery Time :40~45 days
Packaging Details :Plywood wooden box or stretch film +pallet
AHU Type :Direct expansion type
Mounting :Floor standing
Advantage A :PLC precise temperature and humidity control
Advantage C :EC fan
Advantage D :Compact structure
Advantage E :Inverter compressor
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Close Control Clean Room Air Conditioning System For PCR Laboratory

Feature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design.

Standard DX AHU Technical Paramater:
Unit characteristics Model: SL-ZKW-( ) DX 20 30 40 50 65 80 100
Cooling capacity 1* kw 10.1 15.3 20.3 25.5 32.3 38.6 52.0
Heating capacity 2* kw 10.3 15.7 20.8 26.1 33.5 39.5 53.2
Air volume 3* m3/h 2000 3000 4000 5000 6500 8000 10000
Static air pressure 3* Pa 200 250 300 300 400 400 500
power 3N-380V-50Hz
Indoor unit Supply air fan 3* Type Efficient centrifugal fan
kw 0.55 0.75 1.5 2.2 3.0 3.0 5.5
Chilled water coil 4*(option) Type Efficient copper tube and aluminum fin
Flow m3/h 1.7 2.6 3.5 4.4 5.6 6.6 8.9
Section length(mm) 300 300 300 300 300 300 300
Heater 5* Type Stainless steel tube electric heating/ steam heating coil/hot water heating coil
kw 6 9 12 18 24 24 30
Section length(mm) 300 300 300 300 400 400 400
Humidifier 5* Type Electrode type/steam/electrothermic type/wet film
kg/h 3 4 5 8 8 12 12
Section length(mm) 400 400 400 400 400 400 400
Filter 6* Type Primary filter G4(medium effect F8/ Nanocrystalline carbon filter
Noise dB(A) 60 60 61 62 63 63 65
Overall dimension 7* Length(mm) 1800 2000 2000 2100 2100 2200 2400
Width(mm) 730 1030 1030 1030 1140 1340 1340
Height(mm) 788 788 1115 1115 1115 1115 1420
Weight kg 40 180 320 400 580 660 800
Outdoor unit Model: SL-WL 10 15 20 25 35 40 55
Compressor A Type Hermetic scroll type (Fixed frequency system)
Qty 1 1 1 1 1 2 2
Input power A kw 3.4 4.8 6.3 8.0 9.8 12.7 16.1
Compressor B Type Hermetic scroll type (Inverter system)
Qty 1 1 1 1 1 2 2
Input power B kw 3.3 4.6 6.2 7.7 9.7 12.6 15.6
Refrigerant 8* Type R22/R407C/R410A
Mode External balance type thermal expansion valve/electronic expansion valve
Noise 9* dB(A) 63 63 64 64 65 65 67
Overall dimension Length(mm) 850 850 980 980 980 1880 1880
Width(mm) 850 850 980 980 980 1880 1880
Height(mm) 1080 1080 1080 1080 1234 1080 1080
Weight kg 130 135 150 180 220 280 320
Connection pipe size 10* Liquid pipe(mm) 12.7(9.52) 12.7(9.52) 12.7(12.7) 15.88(12.7) 15.88(12.7) 15.88*2(12.7*2) 15.88*2(12.7*2)
Steam pipe(mm) 15.88(12.7) 19.05(15.88) 19.05(15.88) 28.6(22.23) 28.6(22.23) 22.23*2(19.05*2 28.6*2(22.23*2)

1. Cooling condition: indoor dry bulb/wet bulb 27/19℃; outdoor dry bulb/wet bulb 35/24℃

2. Heating condition: indoor dry bulb/wet bulb 20/-℃; outdoor dry bulb/wet bulb 7/6℃

3. Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer`s requirements

4. Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit.

5. Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the other forms.

6. Unit standard uses G4 level filters, according to the customer requirements configured to the other forms.

7. Unit length does not include the function section .Such as heating section, humidification section. Specific details please consult us.

8. Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to be indicated in the order.

9. Noise data is measured 2m in front of the unit, 1.2m high, when cooling under the standard air volume.

11.Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.