Brand Name :Shenglin
Model Number :SLZK Series
Certification :CE
Place of Origin :China
MOQ :1
Price :5000~10000USD/unit
Payment Terms :T/T, Western Union
Supply Ability :100 Units Per Month
Delivery Time :35~40days
Packaging Details :Plywood wooden box or stretch film +pallet
AHU Type :Dx type
Mounting :Floor standing
Advantage A :PLC precise temperature and humidity control
Advantage C :EC fan
Advantage D :Compact structure
Advantage E :Inverter compressor
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Non-standard Customization Purification Air Conditioning Unit For PCR Detection

Feature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design.

Clean operating room air conditioning system solution Ⅰ

l DC frequency conversion outdoor unit + clean operating room air conditioning unit + PLC intelligent control

Non Standard Purification Vertical AHU Clean Room Air Handling Units

1,Frequency conversion technology: The DC frequency conversion compressor is used to adjust the operating frequency of the compressor according to the temperature change, which is efficient and energy-saving

2,Low ambient temperature cooling: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;

3,Low temperature air supply: Shenglin's unique technology, through the grading and separate control of the evaporator, reduces the evaporation temperature, and the minimum air supply temperature is 5℃;

4,Precise temperature control: electric reheating and electric preheating are steplessly adjusted by SCR to accurately control the indoor temperature

5,Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20°C.

Air conditioning system solution for clean operating room Ⅱ

l Four-pipe air-cooled heat pump heat recovery unit + clean operating room combined air conditioner + PLC control

Non Standard Purification Vertical AHU Clean Room Air Handling Units

Multi-function: four-pipe, frequency conversion adjustment, cooling and heating operation can realize energy recovery at the same time, no need to add a hot water tank to adjust the water capacity on the hot water side;

Low-temperature heating: Adopting jet enthalpy and high-temperature liquid injection technology, heating operation at minus 20℃, and energy efficiency ratio higher than 2.1;

Low temperature refrigeration: EC fan is used to detect the discharge pressure of the compressor to achieve normal refrigeration at -20°C,

Cooling and heating balance: automatic cooling and heating balance under partial cooling and heating load, automatic distribution of refrigerant flow;

System stability: Adopting single four-valve design, consistent operation, mature system technology, stable and reliable operation;

Energy saving and environmental protection: annual heat recovery can be realized, energy recovery can be adjusted, cooling energy efficiency ratio ≥ 4.0, while heat energy efficiency ratio ≥ 5.0, combined cooling and heating energy efficiency ratio ≥ 9.0, operation energy saving effect is more significant ;

Intelligent control: Microcomputer PLC control technology, automatically detects the operating status, and realizes energy-saving operation;

Fault self-check: automatic fault detection system can detect operation faults such as suction and exhaust pressure, exhaust temperature, phase loss and reverse phase, overcurrent and overload;

Unique technology: the perfect combination of single four-way valve design, ultra-low temperature heating design, low temperature refrigeration design, and stable mode conversion.

Clean operating room air conditioning system solution Ⅲ

l Air-cooled heat pump + clean operating room combined air conditioning unit + PLC control

Non Standard Purification Vertical AHU Clean Room Air Handling Units

Precise temperature control: DC inverter compressor is used, and the operating power of the compressor is self-matched according to changes in ambient temperature;

Low ambient temperature refrigeration: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;

Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20℃;

Intelligent defrosting: super-cooling ice suppression technology, combined with Sunlin’s unique defrosting module, with frost defrosting, frost-free heating

Smart cloud service: PC client + mobile App real-time monitoring.

Standard AHU model representation method:

Non Standard Purification Vertical AHU Clean Room Air Handling Units

Unit quick selection table (air volume)

Model Nominal air volume m³/h Windward area of coil㎡ Wind speed of the coil(m/s)
2.00 2.25 2.50 2.75 3.00 3.25
m³/h
SLZK015W 1500 0.16 1152 1296 1440 1584 1728 1872
SLZK018W 1800 0.2 1440 1620 1800 1980 2160 2340
SLZK022W 2200 0.24 1728 1944 2160 2376 2592 2808
SLZK032W 3200 0.35 2520 2835 3150 3465 3780 4095
SLZK038W 3800 0.42 3024 3402 3780 4158 4536 4914
SLZK050W 5000 0.56 4032 4536 5040 5544 6048 6552
SLZK063W 6300 0.7 5040 5670 6300 6930 7560 8190
SLZK072W 7200 0.8 5760 6480 7200 7920 8640 9360
SLZK095W 9500 1.04 7488 8424 9360 10296 11232 12168
SLZK120W 12000 1.3 9360 10530 11700 12870 14040 15210
SLZK150W 15000 1.69 12168 13689 15210 16731 18252 19773
SLZK180W 18000 2.08 14976 16848 18720 20592 22464 24336
SLZK230W 23000 2.56 18432 20736 23040 25344 27648 29952
SLZK270W 27000 3.04 21888 24624 27360 30096 32832 35568
SLZK320W 32000 3.61 25992 29241 32490 35739 38988 42237
SLZK370W 37000 4.18 30096 33858 37620 41382 45144 48906
SLZK430W 43000 4.75 34200 38475 42750 47025 51300 55575
SLZK500W 50000 5.5 39600 44550 49500 54450 59400 64350
SLZK550W 55000 6.16 44352 49896 55440 60984 66528 72072
SLZK630W 63000 7 50400 56700 63000 69300 75600 81900
SLZK700W 70000 7.84 56448 63504 70560 77616 84672 91728
SLZK760W 76000 8.5 61200 68850 76500 84150 91800 99450
SLZK850W 85000 9.52 68544 77112 85680 94248 102816 111384
SLZK930W 93000 10.36 74592 83916 93240 102564 111888 121212
SLZK1000W 100000 11.47 82584 92907 103230 113553 123876 134199
SLZK1100W 110000 12.58 90576 101898 113220 124542 135864 147186

Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.

Unit quick selection table (cooling capacity of coil section under return air condition)

Model Nominal air volume m³/h 4 rows 6 rows 8 rows
Cooling capacity Water volume Cooling capacity Water volume Cooling capacity Water volume
kW m³/h kW m³/h kW m³/h
SLZK015W 1500 8.2 1.4 10.9 1.87 13.2 2.27
SLZK018W 1800 10.2 1.8 13.6 2.34 16.5 2.84
SLZK022W 2200 12.6 2.2 16.4 2.82 19.8 3.41
SLZK032W 3200 17.8 3.1 23.8 4.09 28.8 4.95
SLZK038W 3800 21.5 3.7 28.6 4.92 34.6 5.95
SLZK050W 5000 28.7 4.9 38.1 6.55 46.2 7.95
SLZK063W 6300 35.8 6.2 47.8 8.22 57.5 9.89
SLZK072W 7200 41.1 7.1 54.6 9.39 66.1 11.37
SLZK095W 9500 53.3 9.2 70.8 12.18 85.6 14.72
SLZK120W 12000 66.7 11.5 88.6 15.24 107.1 18.42
SLZK150W 15000 86.6 14.9 115.3 19.83 138.6 23.84
SLZK180W 18000 106.5 18.3 141.8 24.39 170.3 29.29
SLZK230W 23000 131.2 22.6 172.9 29.74 210.5 36.21
SLZK270W 27000 155.8 26.8 206.8 35.57 248.6 42.76
SLZK320W 32000 185.1 31.8 245.2 42.17 296.5 51.00
SLZK370W 37000 214.2 36.8 285.1 49.04 341.8 58.79
SLZK430W 43000 243.3 41.8 323.6 55.66 385.6 66.32
SLZK500W 50000 281.5 48.4 374.5 64.41 450.3 77.45
SLZK550W 55000 315.7 54.3 419.3 72.12 500.4 86.07
SLZK630W 63000 358.6 61.7 476.5 81.96 560.4 96.39
SLZK700W 70000 400.5 68.9 534.1 91.87 640.5 110.17
SLZK760W 76000 432.6 74.4 578.2 99.45 690.5 118.77
SLZK850W 85000 482.5 83.0 645.8 111.08 765.8 131.72
SLZK930W 93000 520.6 89.5 702.3 120.80 830.5 142.85
SLZK1000W 100000 576.1 99.1 778.4 133.88 940.8 161.82
SLZK1100W 110000 630.6 108.5 850.6 146.30 970.5 166.93

Note:

1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;

2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;

3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.