R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp

Ask Latest Price
Brand Name :Shenglin
Model Number :SRF Series
Certification :CE
Place of Origin :China
MOQ :1
Price :4000~30050 USD/unit
Payment Terms :T/T, Western Union
Supply Ability :50~100 units/ month
Delivery Time :40~45days
Packaging Details :Stretch film+ pallet for container loading
Heat pump type :Cooling and heating
Compressor type :Fully enclosed vortex
Evaporator type :Inner grooved copper tube and aluminum fin
Condenser type :Inner grooved copper tube and aluminum fin
Operating voltage :380~400V 3N 50Hz or 60Hz
Refrigerant :R407C or R22 Or R410A
Fan :Forward curve centrifugal fans for air treatment section and axial fans for condensation section
Mounting :Floor standing
Keyword :Rooftop AC Systems
Customized A :With UV lamp
Customized B :Frame colour can follow customer required
Customized C :Free cooling economizer
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp

Rooftop systems offer a flexible way to provide treated air for one to eight-story buildings. Many options and configurations are available to satisfy a wide number of applications. Fresh outside air is mixed with return air from the occupied space and then filtered, conditioned, and supplied back into the building. Conditioning involves cooling, dehumidifying, or heating the air for optimal space comfort. Rooftop units can serve a single zone, or an entire building filled with many zones. Some units can be specifically designed for make-up air, where only outside air is treated and sent to the space. Inverter compressors, belt-less EC fans, and energy recovery solutions make rooftop systems an easy-to-maintain, energy-efficient choice for conditioning any space. Electric, hot water, steam, and heat pump heat provide reliable heating for spaces with colder seasons and climates.

Main Features

Efficient Operation Our packaged rooftop units cut energy costs significantly while meeting all applicable code compliance requirements.
Simplified Installation Embedded Smart Equipment and thoughtful design features make installation, start-up and commissioning faster and more accurate.
Integrated Flexibility Field-installed accessories and an array of heating and air conditioning options help meet the needs of more applications.
Note Can be customized

Application:

Used in a large number of fresh air and exhaust air conditioning system.
Such as laboratory, for security needs, must be a lot of wind, which also need to add fresh air, if you can recover the energy of exhaust, to preheat or pre cooling fresh air can be a lot of energy.
Full heat recovery can recover latent heat, and partial heat recovery can not be.
Where it can achieve the recovery of phase change heat of the occasion, can use the full heat recovery technology.

Technical parameter:

Model SRF12ZA SRF 15ZA SRF18ZA SRF24ZA SRF30ZA SRF35ZA
SF12ZA SF15ZA SF18ZA SF24ZA SF30ZA SF35ZA
Nominal cooling capacity kW 12 15.2 17.5 24 30.3 35.6
Nominal heating capacity kW 13.2 16.6 18.4 26.5 33.3 37.7
Energy regulation % 0,100% 0,50,100%
Power supply 380V / 3Ph / 50HZA
Cooling input capacity kW 4.1 5.3 5.5 8.8 11.3 12.3
Heating input capacity kW 3.8 4.8 5.1 8.2 10.4 11.3
Start current A 48 62 63 63 74 76
Cooling running current A 7.4 9.7 10.2 16.1 21.2 23.3
Heating running current A 6.9 9.2 9.7 15.1 20.1 22.2
Throttling method Thermal expansion valve
Cooling system 1 1 1 1 2 2
Refrigerant R410A
Compressor Type Hermetic scroll compressor
Qty 1 1 1 1 2 2
Condensation side
Condenser Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Drive type Direct drive
Motor power kW 0.25 0.37 0.37 0.55 0.75 0.75
Air volume m3 /h 4600 7800 7800 9000 12600 12600
Evaporation side
Evaporator Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Motor power kW 0.32 0.37 0.45 1.1 1.5 2.2
Air volume m3 /h 2100 2600 3400 4100 5200 6300
Drive type Direct drive Pulley
Static pressure(Pa) 100 100 100 200 200 250
Filter Aluminum filter G3
Noise dB(A) 67 67 68 71 72 72
Refrigerant filling volume(kg) 3.1 3.1 4.3 2x3.1 2x3.1 2x4.3
Overall dimensions Length(mm) mm 1410 1410 1410 1978 1978 1978
Width(mm) mm 1100 1100 1100 1175 1175 1175
Height(mm) mm 1095 1095 1095 1095 1095 1095
Weight kg 240 260 290 420 480 500

1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;

2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;

Workshop showing:

R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp
R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp R410A Commercial Packaged Rooftop AC Systems Cooling And Heating With UV lamp

Pre-Sales Service:
* Inquiry and consulting support.
* Sample testing.
* View our Factory.

After-Sales Service:
* Training how to instal the machine, training how to use the machine in the factory.
* Engineers available to service machinery overseas.

Inquiry Cart 0