Brand Name :Shenglin
Model Number :SRF Series
Certification :CE
Place of Origin :China
MOQ :1
Price :4000~30010 USD/unit
Payment Terms :T/T, Western Union
Supply Ability :50~100 units/ month
Delivery Time :40~45days
Packaging Details :Stretch film+ pallet for container loading
Heat pump type :Cooling and heating
Compressor type :Scroll
Evaporator type :Inner grooved copper tube and aluminum fin
Condenser type :Inner grooved copper tube and aluminum fin
Operating voltage :380~400V 3N 50HZ
Refrigerant :R410A, R134A, R407C, R22
Fan :Forward curve centrifugal fans for air treatment section and axial fans for condensation section
Keyword :Single-Packaged Rooftop Units
Heating Options :Electric, Hot Water, Steam
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High Efficiency Single-Packaged Rooftop Units Packaged Air Conditioners​

Rooftop systems offer a flexible way to provide treated air for one to eight-story buildings. Many options and configurations are available to satisfy a wide number of applications. Fresh outside air is mixed with return air from the occupied space and then filtered, conditioned, and supplied back into the building. Conditioning involves cooling, dehumidifying, or heating the air for optimal space comfort. Rooftop units can serve a single zone, or an entire building filled with many zones. Some units can be specifically designed for make-up air, where only outside air is treated and sent to the space. Inverter compressors, belt-less EC fans, and energy recovery solutions make rooftop systems an easy-to-maintain, energy-efficient choice for conditioning any space. Electric, hot water, steam, and heat pump heat provide reliable heating for spaces with colder seasons and climates.

Features

Energy-efficient compressor with internal relief valve
Multi-speed EC fan optional
Quiet horizontal discharge
Copper tube / aluminum fin condenser and evaporator coil

Technical parameter:

Model SRF45ZA SRF50ZA SRF60ZA SRF72ZA SRF90ZA SRF105ZA
SF45ZA SF50ZA SF60ZA SF72ZA SF90ZA SF105ZA
Nominal cooling capacity kW 44.5 50 60 70 90 105
Nominal heating capacity kW 48.7 54.3 64 75.4 96.2 113.2
Energy regulation % 0,33,66,100 0,30,70,100 0,50,100 0,50,100 0,33,66,100 0,33,66,100
Power supply 380V / 3Ph / 50HZA
Cooling input capacity kW 17 19.5 22.8 26.7 32.9 39.7
Heating input capacity kW 15.6 18 21 24.8 30.4 36.7
Start current A 168 186 175 199 197 266
Cooling running current A 31.7 35.6 39.9 48.3 61 70.6
Heating running current A 29.9 33.5 37.5 45.4 57.3 66.3
Throttling method Thermal expansion valve
Cooling system 1
Refrigerant R410A
Compressor Type Hermetic scroll compressor
Qty 2 2 2 2 3 3
Condensation side
Condenser Type Copper pipe copper fin
Fan Qty 1 1 1 1 2 2
Drive type Direct drive
Motor power kW 1.1 1.5 1.5 2.2 2X1.1 2X1.5
Air volume m3 /h 16500 21000 21000 27000 33000 42000
a 2.65 3.82 3.82 5.49 2.65 3.82
kw 1.14 2.02 2.02 2.875 1.14 2.02
Evaporation side
Evaporator Type Evaporator
Qty 1 1 1 1 1
Motor power 3 3 4 4 5.5 5.5
Air volume 7600 8500 10900 12500 16000 19500
Drive type
Static pressure(Pa) 250 250 300 300 300 300
Filter Aluminum filter G3
Noise dB(A) 73 73 73 75 74 75
Refrigerant filling volume(kg) 4.3+ 4.3+8.5 2x7.5 2x8.5 3x7.5 3x8.5
Overall dimensions Length(mm) mm 2268 2268 2298 2298 2878 2878
Width(mm) mm 1440 1440 1650 1650 2140 2140
Height(mm) mm 1167 1167 1400 1400 1964 1964
Weight 750 770 880 960 1160 1350

1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;

2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;

Model SRF120ZA SRF140ZA SRF150ZA SRF180ZA SRF210ZA SRF300ZA
SF120ZA SF140ZA SF150ZA SF180ZA SF210ZA SF300ZA
Nominal cooling capacity kW 120 140 149 180 210 298
Nominal heating capacity kW 128.3 150 159.2 192.5 226 318

Energy regulation

% 0,25,50,75,100 0,50,100 0,16.6,33.3,50,66.4,83,100 0,25,50,75,100
Power supply 380V / 3Ph / 50HZA
Cooling input capacity kW 45.1 55.7 55.1 69.9 83 106.7
Heating input capacity kW 41.7 51.8 51.5 64.8 77 100
Start current A 218 252 323 232 301 415
Cooling running current A 82.4 101.4 100.2 130.9 151 192.3
Heating running current A 77.4 95.7 95.1 123.5 142.3 184.3
Throttling method Thermal expansion valve
Cooling system 4 4 2 6 6 4
Refrigerant R410A
Compressor Type Hermetic scroll compressor 380V / 3Ph / 50HZA
Qty 4 4 2 6 6 4
Condensation side
Condenser Type Copper pipe copper fin
Fan Qty 2 2 2 4 4 4
Drive type Direct drive
Motor power kW 2X1.5 2x2.2 2x2.2 4X1.1 4X1.5 4x2.2
Air volume m3 /h 42000 54000 54000 66000 84000 108000
Evaporation side
Evaporator Type Copper pipe copper fin
Qty 1 1 1 1 1 1
Motor power kW 7.5 11 11 15 15 18.5
Air volume m3 /h 21000 25000 26000 32000 38000 54000
Drive type Pulley
Static pressure(Pa) 400 400 500 500 500
Filter Aluminum filter G3
Noise dB(A) 75 79 79 80 80 82
Refrigerant filling volume(kg) 4x7.5 4x8.5 2x17 6x7.5 6x8.5 4x14
Overall dimensions Length(mm) mm 3626 3626 3626 4690 4690 5660
Width(mm) mm 2200 2200 2200 2330 2330 2330
Height(mm) mm 2047 2047 2047 2055 2427 2055
Weight kg 1710 1820 1850 2180 2430 2860

1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;

2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;

Preferred Usage Areas
Commercial Building Air Conditioning
Hotel Air Conditioning
Airport Air Conditioning

Workshop showing:

16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan 16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan 16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan
16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan 16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan 16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan

Some overseas project:
16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan

Packing:
16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan 16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan16500m3/H  Single Packaged Rooftop AC Unit Multispeed EC Fan

After-Sales Service:
1. If the project needs our installation guidance, we can send our engineer and translator, but not free. We can also send customers installation video to teach them how to fix and operate with our product.

2. Usually, our product warranty is 18 months after leaving factory or 12 months after installation. within this months, all parts broken will be responsible for our factory.

Inquiry Cart 0