Add to Cart
Rooftop Ac Unit Suitable For Textile factory Free Cooling Function Optional
Rooftop systems offer a flexible way to provide treated air for one to eight-story buildings. Many options and configurations are available to satisfy a wide number of applications. Fresh outside air is mixed with return air from the occupied space and then filtered, conditioned, and supplied back into the building. Conditioning involves cooling, dehumidifying, or heating the air for optimal space comfort. Rooftop units can serve a single zone, or an entire building filled with many zones. Some units can be specifically designed for make-up air, where only outside air is treated and sent to the space. Inverter compressors, belt-less EC fans, and energy recovery solutions make rooftop systems an easy-to-maintain, energy-efficient choice for conditioning any space. Electric, hot water, steam, and heat pump heat provide reliable heating for spaces with colder seasons and climates.
Main Features Of Rooftop Air Conditioner:
1. Various products and wide application
The series of Rooftop units include many different specifications which can completely meet the demand of home and commercial places and offer you a comfortable and pleasant environment.
2. Complete air system, simple and hygiene, less components, easy maintenance. The flexible and concise design makes the maintenance very simple. Disassembling several bolts from any side of the unit can repair any part of the unit.
3. Microcomputer intelligent controller can reach four control modes: cooling, dehumidifying, and ventilation. It also has the functions of timing on-off and failure display.
Application:
Technical parameter:
Model | SRF12ZA | SRF 15ZA | SRF18ZA | SRF24ZA | SRF30ZA | SRF35ZA | ||||
SF12ZA | SF15ZA | SF18ZA | SF24ZA | SF30ZA | SF35ZA | |||||
Nominal cooling capacity | kW | 12 | 15.2 | 17.5 | 24 | 30.3 | 35.6 | |||
Nominal heating capacity | kW | 13.2 | 16.6 | 18.4 | 26.5 | 33.3 | 37.7 | |||
Energy regulation | % | 0,100% | 0,50,100% | |||||||
Power supply | 380V / 3Ph / 50HZA | |||||||||
Cooling input capacity | kW | 4.1 | 5.3 | 5.5 | 8.8 | 11.3 | 12.3 | |||
Heating input capacity | kW | 3.8 | 4.8 | 5.1 | 8.2 | 10.4 | 11.3 | |||
Start current | A | 48 | 62 | 63 | 63 | 74 | 76 | |||
Cooling running current | A | 7.4 | 9.7 | 10.2 | 16.1 | 21.2 | 23.3 | |||
Heating running current | A | 6.9 | 9.2 | 9.7 | 15.1 | 20.1 | 22.2 | |||
Throttling method | Thermal expansion valve | |||||||||
Cooling system | 1 | 1 | 1 | 1 | 2 | 2 | ||||
Refrigerant | R410A | |||||||||
Compressor | Type | Hermetic scroll compressor | ||||||||
Qty | 1 | 1 | 1 | 1 | 2 | 2 | ||||
Condensation side | ||||||||||
Condenser | Type | Copper tube and aluminum fin | ||||||||
Qty | 1 | 1 | 1 | 1 | 1 | 1 | ||||
Drive type | Direct drive | |||||||||
Motor power | kW | 0.25 | 0.37 | 0.37 | 0.55 | 0.75 | 0.75 | |||
Air volume | m3 /h | 4600 | 7800 | 7800 | 9000 | 12600 | 12600 | |||
Evaporation side | ||||||||||
Evaporator | Type | Copper tube and aluminum fin | ||||||||
Qty | 1 | 1 | 1 | 1 | 1 | 1 | ||||
Motor power | kW | 0.32 | 0.37 | 0.45 | 1.1 | 1.5 | 2.2 | |||
Air volume | m3 /h | 2100 | 2600 | 3400 | 4100 | 5200 | 6300 | |||
Drive type | Direct drive | Pulley | ||||||||
Static pressure(Pa) | 100 | 100 | 100 | 200 | 200 | 250 | ||||
Filter | Aluminum filter G3 | |||||||||
Noise dB(A) | 67 | 67 | 68 | 71 | 72 | 72 | ||||
Refrigerant filling volume(kg) | 3.1 | 3.1 | 4.3 | 2x3.1 | 2x3.1 | 2x4.3 | ||||
Overall dimensions | Length(mm) | mm | 1410 | 1410 | 1410 | 1978 | 1978 | 1978 | ||
Width(mm) | mm | 1100 | 1100 | 1100 | 1175 | 1175 | 1175 | |||
Height(mm) | mm | 1095 | 1095 | 1095 | 1095 | 1095 | 1095 | |||
Weight | kg | 240 | 260 | 290 | 420 | 480 | 500 |
1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;
Workshop showing:
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Some overseas project:
Pre-Sales Service:
* Inquiry and consulting support.
* Sample testing.
* View our Factory.
After-Sales Service:
* Training how to instal the machine, training how to use the machine.
* Engineers available to service machinery overseas.