R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing

Ask Latest Price
Video Channel
Brand Name :Shenglin
Model Number :SRF Series
Certification :CE
Place of Origin :China
MOQ :1
Payment Terms :T/T, Western Union
Supply Ability :50~100 units/ month
Delivery Time :40~45days
Packaging Details :Stretch film+ pallet for container loading
Heat pump type :Cooling
Compressor type :Scroll
Evaporator type :Epoxy aluminum fin heat exchanger
Condenser type :Epoxy aluminum fin heat exchanger
Operating voltage :380~400V 3N 50HZ
Refrigerant :R407C or R22
Fan :EC frequency conversion fan
Mounting :Floor standing
Bolt material :Stainless steel SUS304
Keyword :Rooftop Ac Unit
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

T3 Working Condition Rooftop Ac Unit Suitable For The Middle East Country

Description:

1. Rooftop air conditioner generally have many functions such as refrigeration,heating,air supply,easy to use,low cost installation, low maintenance cost, widely used in air conditioning engineering project.

2. Rooftop air conditioner,saving the cooling tower and cooling water pump cost for customers, is particularly suitable for water shortage area.It does not need special room for installation, and can be installed on the roof or building ground outside

3. package unit heat pump is widely used in large space of centralized air treatment, such as convention and exhibition center,stadiums, theatres, shopping malls, supermarkets, waiting room, conference room, production workshop, library,etc.

4. It is equipped with high performance compressor,low noise axial flow fan, high precision grades of electronic expansion valve,and advanced control system.

Structure:
1. Frame: channel steel sandblasting, then primer, then topcoat (sometimes primer and topcoat are also brushed with 2 coats), bolts SS304.
2. Epoxy aluminum fin heat exchangers.
3. Can be used under T3 working conditions and can withstand an environment of up to 55°c (for 2 reasons):
A. Parallel compressors (can be stopped when the ambient temperature is high, and one compressor can be stopped when the ambient temperature is the highest.

B. All fans are EC frequency conversion, stepless speed regulation (continuous speed regulation).
Technical paramater:
Model SRF12ZA SRF 15ZA SRF18ZA SRF24ZA SRF30ZA SRF35ZA
SF12ZA SF15ZA SF18ZA SF24ZA SF30ZA SF35ZA
Nominal cooling capacity kW 12 15.2 17.5 24 30.3 35.6
Nominal heating capacity kW 13.2 16.6 18.4 26.5 33.3 37.7
Energy regulation % 0,100% 0,50,100%
Power supply 380V / 3Ph / 50HZA
Cooling input capacity kW 4.1 5.3 5.5 8.8 11.3 12.3
Heating input capacity kW 3.8 4.8 5.1 8.2 10.4 11.3
Start current A 48 62 63 63 74 76
Cooling running current A 7.4 9.7 10.2 16.1 21.2 23.3
Heating running current A 6.9 9.2 9.7 15.1 20.1 22.2
Throttling method Thermal expansion valve
Cooling system 1 1 1 1 2 2
Refrigerant R410A
Compressor Type Hermetic scroll compressor
Qty 1 1 1 1 2 2
Condensation side
Condenser Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Drive type Direct drive
Motor power kW 0.25 0.37 0.37 0.55 0.75 0.75
Air volume m3 /h 4600 7800 7800 9000 12600 12600
Evaporation side
Evaporator Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Motor power kW 0.32 0.37 0.45 1.1 1.5 2.2
Air volume m3 /h 2100 2600 3400 4100 5200 6300
Drive type Direct drive Pulley
Static pressure(Pa) 100 100 100 200 200 250
Filter Aluminum filter G3
Noise dB(A) 67 67 68 71 72 72
Refrigerant filling volume(kg) 3.1 3.1 4.3 2x3.1 2x3.1 2x4.3
Overall dimensions Length(mm) mm 1410 1410 1410 1978 1978 1978
Width(mm) mm 1100 1100 1100 1175 1175 1175
Height(mm) mm 1095 1095 1095 1095 1095 1095
Weight kg 240 260 290 420 480 500
Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;

Preferred Usage Areas
Commercial Building Air Conditioning
Hotel Air Conditioning
Airport Air Conditioning

Some overseas project:
R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing

Pre-Sales Service:
* Inquiry and consulting support.
* Sample testing.
* View our Factory.

After-Sales Service:
* Training how to instal the machine, training how to use the machine.
* Engineers available to service machinery overseas.

Inquiry Cart 0