Shanghai Shenglin M&E Technology Co., Ltd.

Shanghai Shenglin M&E Technology Co., Ltd.

Manufacturer from China
Active Member
5 Years
Home / Products / Clean Room HVAC Equipment /

Package Type Hygienic Air Handling Units Clean Room HVAC Equipment

Contact Now
Shanghai Shenglin M&E Technology Co., Ltd.
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrJason
Contact Now

Package Type Hygienic Air Handling Units Clean Room HVAC Equipment

Ask Latest Price
Brand Name :Shenglin
Model Number :SLZK Series
Certification :CE
Place of Origin :China
MOQ :1
Price :5001~10008 USD/unit
Payment Terms :T/T, Western Union
Supply Ability :100 Units Per Month
Delivery Time :35~45 days
Packaging Details :Plywood wooden box or stretch film +pallet
Indoor Unit :Chilled water air handling unit
Outdoor unit :Air-cooled modular heat pump
Mounting :Floor standing or ceiling mounting
Advantage A :Precise temperature control
Advantage B :Low ambient temperature refrigeration
Advantage C :Low ring temperature heating
Advantage D :Intelligent defrosting
Advantage E :Smart cloud service
Condition :Fresh air or fresh/return air condition
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Package Type Hygienic Air Handling Units Clean Room HVAC Equipment

Package Type Hygienic Air Handling Units Clean Room HVAC Equipment

According to the clean operating room design specifications, the clean air conditioning system must have core technical indicators such as constant temperature, constant humidity, fresh air treatment, air purification, and ensuring the positive and negative pressure difference in the controlled area to achieve the design requirements for controlling the concentration of bacteria and reducing the risk of infection. Clean air conditioners have multiple functions such as air purification, transportation, cooling, dehumidification, humidification, heating, heat recovery, and intelligent control, providing users with clean environment system solutions suitable for different purification levels and different working conditions.

AHU model representation method:

Package Type Hygienic Air Handling Units Clean Room HVAC Equipment

Unit quick selection table (air volume)

Model Nominal air volume m³/h Windward area of coil㎡ Wind speed of the coil(m/s)
2.00 2.25 2.50 2.75 3.00 3.25
m³/h
SLZK015W 1500 0.16 1152 1296 1440 1584 1728 1872
SLZK018W 1800 0.2 1440 1620 1800 1980 2160 2340
SLZK022W 2200 0.24 1728 1944 2160 2376 2592 2808
SLZK032W 3200 0.35 2520 2835 3150 3465 3780 4095
SLZK038W 3800 0.42 3024 3402 3780 4158 4536 4914
SLZK050W 5000 0.56 4032 4536 5040 5544 6048 6552
SLZK063W 6300 0.7 5040 5670 6300 6930 7560 8190
SLZK072W 7200 0.8 5760 6480 7200 7920 8640 9360
SLZK095W 9500 1.04 7488 8424 9360 10296 11232 12168
SLZK120W 12000 1.3 9360 10530 11700 12870 14040 15210
SLZK150W 15000 1.69 12168 13689 15210 16731 18252 19773
SLZK180W 18000 2.08 14976 16848 18720 20592 22464 24336
SLZK230W 23000 2.56 18432 20736 23040 25344 27648 29952
SLZK270W 27000 3.04 21888 24624 27360 30096 32832 35568
SLZK320W 32000 3.61 25992 29241 32490 35739 38988 42237
SLZK370W 37000 4.18 30096 33858 37620 41382 45144 48906
SLZK430W 43000 4.75 34200 38475 42750 47025 51300 55575
SLZK500W 50000 5.5 39600 44550 49500 54450 59400 64350
SLZK550W 55000 6.16 44352 49896 55440 60984 66528 72072
SLZK630W 63000 7 50400 56700 63000 69300 75600 81900
SLZK700W 70000 7.84 56448 63504 70560 77616 84672 91728
SLZK760W 76000 8.5 61200 68850 76500 84150 91800 99450
SLZK850W 85000 9.52 68544 77112 85680 94248 102816 111384
SLZK930W 93000 10.36 74592 83916 93240 102564 111888 121212
SLZK1000W 100000 11.47 82584 92907 103230 113553 123876 134199
SLZK1100W 110000 12.58 90576 101898 113220 124542 135864 147186

Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.

Unit quick selection table (cooling capacity of coil section under return air condition)

Model Nominal air volume m³/h 4 rows 6 rows 8 rows
Cooling capacity Water volume Cooling capacity Water volume Cooling capacity Water volume
kW m³/h kW m³/h kW m³/h
SLZK015W 1500 8.2 1.4 10.9 1.87 13.2 2.27
SLZK018W 1800 10.2 1.8 13.6 2.34 16.5 2.84
SLZK022W 2200 12.6 2.2 16.4 2.82 19.8 3.41
SLZK032W 3200 17.8 3.1 23.8 4.09 28.8 4.95
SLZK038W 3800 21.5 3.7 28.6 4.92 34.6 5.95
SLZK050W 5000 28.7 4.9 38.1 6.55 46.2 7.95
SLZK063W 6300 35.8 6.2 47.8 8.22 57.5 9.89
SLZK072W 7200 41.1 7.1 54.6 9.39 66.1 11.37
SLZK095W 9500 53.3 9.2 70.8 12.18 85.6 14.72
SLZK120W 12000 66.7 11.5 88.6 15.24 107.1 18.42
SLZK150W 15000 86.6 14.9 115.3 19.83 138.6 23.84
SLZK180W 18000 106.5 18.3 141.8 24.39 170.3 29.29
SLZK230W 23000 131.2 22.6 172.9 29.74 210.5 36.21
SLZK270W 27000 155.8 26.8 206.8 35.57 248.6 42.76
SLZK320W 32000 185.1 31.8 245.2 42.17 296.5 51.00
SLZK370W 37000 214.2 36.8 285.1 49.04 341.8 58.79
SLZK430W 43000 243.3 41.8 323.6 55.66 385.6 66.32
SLZK500W 50000 281.5 48.4 374.5 64.41 450.3 77.45
SLZK550W 55000 315.7 54.3 419.3 72.12 500.4 86.07
SLZK630W 63000 358.6 61.7 476.5 81.96 560.4 96.39
SLZK700W 70000 400.5 68.9 534.1 91.87 640.5 110.17
SLZK760W 76000 432.6 74.4 578.2 99.45 690.5 118.77
SLZK850W 85000 482.5 83.0 645.8 111.08 765.8 131.72
SLZK930W 93000 520.6 89.5 702.3 120.80 830.5 142.85
SLZK1000W 100000 576.1 99.1 778.4 133.88 940.8 161.82
SLZK1100W 110000 630.6 108.5 850.6 146.30 970.5 166.93

Note:

1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;

2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;

3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(cooling capacity of coil section under fresh air condition)

Model Nominal air volume m³/h 4 rows 6 rows 8 rows
Cooling capacity Water volume Cooling capacity Water volume Cooling capacity Water volume
kW m³/h kW m³/h kW m³/h
SLZK015W 1500 18.9 3.3 23.5 4.04 28.1 4.83
SLZK018W 1800 23.5 4.0 29.4 5.06 35.1 6.04
SLZK022W 2200 28.3 4.9 35.3 6.07 42.2 7.25
SLZK032W 3200 41.3 7.1 51.4 8.84 61.5 10.57
SLZK038W 3800 49.5 8.5 61.7 10.61 73.8 12.69
SLZK050W 5000 66.2 11.4 82.3 14.15 98.4 16.92
SLZK063W 6300 82.3 14.2 102.8 17.68 122.9 21.15
SLZK072W 7200 94.5 16.3 117.5 20.21 140.5 24.17
SLZK095W 9500 122.9 21.1 152.8 26.27 182.7 31.42
SLZK120W 12000 153.2 26.4 190.9 32.84 228.3 39.27
SLZK150W 15000 195.6 33.6 248.2 42.69 296.8 51.05
SLZK180W 18000 245.6 42.2 305.5 52.55 365.3 62.83
SLZK230W 23000 302.1 52.0 376.0 64.67 449.6 77.33
SLZK270W 27000 358.7 61.7 446.5 76.80 533.9 91.83
SLZK320W 32000 426.1 73.3 530.2 91.20 634.0 109.05
SLZK370W 37000 492.8 84.8 613.9 105.60 734.1 126.27
SLZK430W 43000 560.8 96.5 697.7 120.00 834.2 143.49
SLZK500W 50000 648.9 111.6 807.8 138.94 965.9 166.14
SLZK550W 55000 727.6 125.1 904.8 155.62 1081.9 186.08
SLZK630W 63000 826.4 142.1 1028.1 176.84 1229.4 211.45
SLZK700W 70000 924.8 159.1 1151.5 198.06 1376.9 236.83
SLZK760W 76000 1005.4 172.9 1248.4 214.73 1492.8 256.76
SLZK850W 85000 1124.3 193.4 1398.3 240.50 1672.0 287.58
SLZK930W 93000 1200.6 206.5 1514.6 260.51 1812.4 311.73
SLZK1000W 100000 1320.6 227.1 1671.4 287.48 2010.3 345.77
SLZK1100W 110000 1450.7 249.5 1825.7 314.02 2186.5 376.08

Note:

1. The inlet temperature of chilled water is 7℃, and the outlet temperature is 12℃;

2. Fresh air conditions: inlet air dry bulb temperature 35℃, wet bulb temperature 28℃;

3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(hot water coil heating capacity)

Model Nominal air volume m³/h Return air condition Fresh air condition
2 rows 3 rows 4 rows 2 rows 3 rows 4 rows
heating capacity heating capacity heating capacity heating capacity heating capacity heating capacity
kW kW kW kW kW kW
SLZK015W 1500 9.4 12.5 14.8 11.1 15.1 18.1
SLZK018W 1800 11.8 15.6 18.5 13.9 18.9 22.6
SLZK022W 2200 14.1 18.8 22.2 16.7 22.7 27.2
SLZK032W 3200 20.6 27.3 32.4 24.3 33.0 39.6
SLZK038W 3800 24.7 32.8 38.9 29.1 39.6 47.5
SLZK050W 5000 32.9 43.8 51.8 38.9 52.9 63.4
SLZK063W 6300 41.1 54.7 64.8 48.6 66.1 79.2
SLZK072W 7200 47.0 62.5 74.0 55.5 75.5 90.5
SLZK095W 9500 61.1 81.3 96.2 72.2 98.2 117.7
SLZK120W 12000 76.4 101.6 120.3 90.2 122.7 147.1
SLZK150W 15000 99.3 132.0 156.3 117.2 159.5 191.2
SLZK180W 18000 122.2 162.5 192.4 144.3 196.3 235.3
SLZK230W 23000 150.4 200.0 236.8 177.6 241.6 289.6
SLZK270W 27000 178.6 237.5 281.2 210.9 286.9 343.9
SLZK320W 32000 212.1 282.0 333.9 250.4 340.7 408.4
SLZK370W 37000 245.6 326.6 386.7 290.0 394.5 472.9
SLZK430W 43000 279.1 371.1 439.4 329.5 448.3 537.3
SLZK500W 50000 323.1 429.7 508.8 381.6 519.1 622.2
SLZK550W 55000 361.9 481.3 569.8 427.4 581.4 696.9
SLZK630W 63000 411.3 546.9 647.5 485.6 660.6 791.9
SLZK700W 70000 460.6 612.5 725.2 543.9 739.9 886.9
SLZK760W 76000 499.4 664.1 786.3 589.7 802.2 961.6
SLZK850W 85000 559.3 743.8 880.6 660.5 898.5 1077.0
SLZK930W 93000 608.7 809.4 958.3 718.7 977.7 1172.0
SLZK1000W 100000 673.9 896.1 1061.0 795.7 1082.5 1297.5
SLZK1100W 110000 739.1 982.8 1163.7 872.7 1187.2 1423.1

Note:

1. The inlet temperature of hot water is 60°C, and the outlet temperature is 50°C;

2. Return air condition: inlet air dry bulb temperature 15℃; fresh air condition: inlet air dry bulb temperature 7℃;

3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Inquiry Cart 0