Add to Cart
Air To Water Heat Pump For Hotel And Villa
Technical paramater:
Air source heat pump | MODEL | Unit | MD40D | ||
Average heating input power | KW | 3.78 | |||
Rated heating capacity | KW | 15 | |||
Hot water supply | L/h | 350 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 160 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 4000L/h | |||
Water pressure down | Kpa | 55 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD50D | ||
Average heating input power | KW | 4.6 | |||
Rated heating capacity | KW | 18.6 | |||
Hot water supply | L/h | 400 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | C | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 170 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 5000L/h | |||
Water pressure down | Kpa | 45 | |||
Pipe size | DN | 25 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD60D | ||
Average heating input power | KW | 5.2 | |||
Rated heating capacity | KW | 21 | |||
Hot water supply | L/h | 500 | |||
Rated heating input current | A | 12 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 180 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 6000L/h | |||
Water pressure down | Kpa | 48 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD100D | ||
Average heating input power | KW | 9.2 | |||
Rated heating capacity | KW | 36 | |||
Hot water supply | L/h | 800 | |||
Rated heating input current | A | 18 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 310 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 10000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Air source heat pump | MODEL | Unit | MD150D | ||
Average heating input power | KW | 11 | |||
Rated heating capacity | KW | 42 | |||
Hot water supply | L/h | 1000 | |||
Rated heating input current | A | 24 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 340 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 12000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD200D | ||
Average heating input power | KW | 19 | |||
Rated heating capacity | KW | 72 | |||
Hot water supply | L/h | 1600 | |||
Rated heating input current | A | 35 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 650 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 20000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 | |||
Air source heat pump | MODEL | Unit | MD300D | ||
Average heating input power | KW | 22 | |||
Rated heating capacity | KW | 84 | |||
Hot water supply | L/h | 2000 | |||
Rated heating input current | A | 40 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 750 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 25000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 |
Parts:
![]() | Heat exchanger type A: fin heat exchanger |
![]() | Heat exchanger type B: coil heat exchanger |
![]() | Heat exchanger type C: plate heat exchanger |
![]() | Electric expansion valve |
![]() | Expansion valve |
![]() | Relay |
![]() | Senssor connector |
![]() | Liquid, gas separator |
![]() | Sensor |
![]() | Thermal expansion valve |
![]() | Control panel |
Simple installation diagram for air source:
Why choose us?
A. Technical service
1. We calculate the capacity and recommend the best models.
2. We supply you the professional refrigeration technical support and electronic technical support for your installation,
debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory if you need, we can also offer site training.
5. We welcome you to be our partner.
B. After-sales service
1. Technical support for your installation, operation and maintenance.
2. Standard warranty time: One year warranty for heat pumps
You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Spare parts and technical support at most economic prices after the warranty.
C. Certificate we have got :
1. CE