
Add to Cart
Unit characteristics | Model: SL-ZKW-( ) DX | 140 | 180 | 240 | 300 | 400 | 500 | 600 | |
Cooling capacity 1* | kw | 68.0 | 90.0 | 120.0 | 148.0 | 200.0 | 240.0 | 300.0 | |
Heating capacity 2* | kw | 69.6 | 92.1 | 122.8 | 151.5 | 204.8 | 248.0 | 304.0 | |
Air volume 3* | m3/h | 14000 | 18000 | 24000 | 30000 | 40000 | 50000 | 60000 | |
Static air pressure 3* | Pa | 500 | 600 | 600 | 750 | 750 | 800 | 800 | |
power | 3N-380V-50Hz | ||||||||
Indoor unit | Supply air fan 3* | Type | Efficient centrifugal fan | ||||||
kw | 7.5 | 11.0 | 15.0 | 18.5 | 22.0 | 30.0 | 37.0 | ||
Chilled water coil 4*(option) | Type | Efficient copper tube and aluminum fin | |||||||
Flow m3/h | 11.7 | 15.5 | 20.6 | 25.4 | 34.4 | 41.2 | 51.6 | ||
Section length(mm) | 300 | 400 | 400 | 400 | 400 | 400 | 400 | ||
Heater 5* | Type | Stainless steel tube electric heating/ steam heating coil/hot water heating coil | |||||||
kw | 36 | 48 | 60 | 72 | 96 | 120 | 150 | ||
Section length(mm) | 400 | 400 | 400 | 400 | 500 | 500 | 600 | ||
Humidifier 5* | Type | Electrode type/steam/electrothermic type/wet film | |||||||
kg/h | 15 | 15 | 21 | 21 | 30 | 45 | 60 | ||
Section length(mm) | 400 | 400 | 600 | 600 | 600 | 600 | 600 | ||
Filter 6* | Type | Primary filter G4(medium effect F8/ Nanocrystalline carbon filter | |||||||
Noise | dB(A) | 65 | 68 | 68 | 72 | 75 | 75 | 80 | |
Overall dimension 7* | Length(mm) | 2600 | 2800 | 3000 | 3000 | 3200 | 3500 | 3800 | |
Width(mm) | 1650 | 1650 | 1960 | 1960 | 2270 | 2580 | 3270 | ||
Height(mm) | 1420 | 1730 | 1730 | 2040 | 2340 | 2650 | 2650 | ||
Weight | kg | 880 | 980 | 1080 | 1180 | 1280 | 1450 | 1800 | |
Outdoor unit | Model: SL-WL | 65 | 45*2 | 120 | 150 | 200 | 120*2 | 150*2 | |
Compressor A | Type | Hermetic scroll type (Fixed frequency system) | |||||||
Qty | 2 | 2*2 | 4 | 4 | 6 | 4*2 | 4*2 | ||
Input power A | kw | 22.4 | 29.2 | 38.2 | 43.4 | 67.2 | 78.0 | 97.2 | |
Compressor B | Type | Hermetic scroll type (Inverter system) | |||||||
Qty | 2 | 2*2 | 4 | 4 | 6 | 4*2 | 4*2 | ||
Input power B | kw | 22.2 | 28.2 | 36.2 | 42.5 | 66.0 | 76.5 | 95.5 | |
Refrigerant 8* | Type | R22/R407C/R410A | |||||||
Mode | External balance type thermal expansion valve/electronic expansion valve | ||||||||
Noise 9* | dB(A) | 67 | 68 | 70 | 72 | 75 | 75 | 78 | |
Overall dimension | Length(mm) | 1880 | 1880*2 | 2250 | 2550 | 3830 | 2250*2 | 2550*2 | |
Width(mm) | 980 | 980 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
Height(mm) | 1234 | 1080 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
Weight | kg | 400 | 320*2 | 950 | 1200 | 1800 | 950*2 | 1200*2 | |
Connection pipe size 10* | Liquid pipe(mm) | 19.05*2 (15.88*2) | 15.88*4 (12.7*4) | 15.88*4 (12.7*4) | 19.05*4 (15.88*4) | 19.05*6 (15.88*6) | 15.88*8 (12.7*8) | 19.05*8 (15.88*8) | |
Steam pipe(mm) | 34.9*2 (28.6*2) | 22.23*4 (19.05*4) | 28.6*4 (22.23*4) | 34.9*4 (28.6*4) | 34.9*6 (28.6*6) | 28.6*8 (22.23*8) | 34.9*8 (28.6*8) |
1. Cooling condition: indoor dry bulb/wet bulb 27/19℃; outdoor dry bulb/wet bulb 35/24℃
2. Heating condition: indoor dry bulb/wet bulb 20/-℃; outdoor dry bulb/wet bulb 7/6℃
3. Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer`s requirements
4. Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit.
5. Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the other forms.
6. Unit standard uses G4 level filters, according to the customer requirements configured to the other forms.
7. Unit length does not include the function section .Such as heating section, humidification section. Specific details please consult us.
8. Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to be indicated in the order.
9. Noise data is measured 2m in front of the unit, 1.2m high, when cooling under the standard air volume.
11.Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.
Our factory:
Air Conditioning Unit Reference:
Country: Turkey Application:distributor Type: heat pump type Cooling capacity: 108.9KW; Heating capacity: 113KW; 380V-3Ph-50hz R410a ESP: 350 Pa; 19940 m3/h 25% fresh air; | Country: Nigeria Application: Pharmaceutical Factory Type: heat pump type Cooling capacity: 36.2kW Heating capacity: 82kW Refrigerant: R407C Compressor: Sanyo | Country: Jordan Application: Textile Factory Type: heat pipe heat recovery type Cooling capacity: 368kW Heating capacity: 359kW Refrigerant: R410A Compressor: Copeland With heat recovery coil | Country: USA Application: Residential Type: heat pump type Cooling capacity: 5 Ton Heating capacity: Refrigerant: R410A Compressor: COP: 3.0 Power supply: 230V/3PH/60Hz |
![]() | ![]() | ![]() | ![]() |
Country:UAE Application:offshore Drilling Platform Cooling capacity: 80kw Supply air volume: 4000×2 m3/h Condensing fan: 12000m3/h Refrigerant: R407C Power supply:430V-3Ph-60Hz Evaporator & condenser type: copper tube epoxy aluminum fin | Country:Australia Application:hall Cooling capacity: 128kw Heating capacity: 135kw Capacity regulator: 0,25,50,75,100 Power supply: 415V/3PH/50hz Refrigerant:R410A | Country:China Application: Amusement park Cooling capacity: 180kw Heating capacity: 192.5kw Supply air volume: 32000m3/h ESP: 550pa Power supply: 380V/3PH/50hz Refrigerant:R22 | Country: Philippines Application: Factory Type: Fresh air type Cooling capacity:21.9kw Heating capacity:25kw Supply air volume: 3000m3/h Electric heating: 6kw Power supply:220v/3PH/60hz 10% fresh air Refrigerant:R410A |
![]() | ![]() | ![]() | ![]() |
Country: China Application: Rolling bearing manufacturer Type: wheel heat recovery type One model: Cooling capacity: 95kw Condensation and heating capacity: 55kw Supply air volume: 19000m3/h Exhaust air volume: 19000m3/h Another model: Cooling capacity: 210kw Heating capacity: 215kw Supply air volume: 38000m3/h Exhaust air volume: 38000m3/h | Country: China Application:Flight simulation system laboratory Cooling capacity:10kw Supply air volume:3000m3/h Power supply: 380V/3PH/50Hz | Country: China Application:Ferry waiting hall Type: heat pump type Cooling capacity:182.5kw Supply air volume: 22000m3/h | Country: China Application: Cool Storehouse Type: constant temperature and constant humidity unit One model: Cooling capacity: 22kW Electric heating capacity: 82kW Humidifying capacity: 6kg/h Supply air: 4500 m3/h Another model: Cooling capacity: 180kW Electric heating capacity: 90kW Humidifying capacity: 30kg/h Supply air: 35000 m3/h |
![]() | ![]() | ![]() | ![]() |