40 ~ 90kW All Fresh Air Type Rooftop Unit
Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
Model:SL-WKX | 40 | 50 | 60 | 80 | 90 | ||||||
Cooling capacity1* | kw | 41.6 | 52.6 | 62.5 | 78.0 | 90.0 | |||||
Heating capacity2* | kw | 23.8 | 33.5 | 36.2 | 51.5 | 58.0 | |||||
Fresh air volume 3* | m3/h | 3000 | 4000 | 4000 | 5000 | 5000 | 6000 | 6000 | 8000 | 7000 | 9000 |
Static Pressure 3* | Pa | 200 | 200 | 250 | 250 | 250 | 250 | 300 | 300 | 300 | 300 |
Fan power 3* | kw | 0.75 | 1.1 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 3.0 | 3.0 | 3.0 |
Noise 4* | dB(A) | 58 | 59 | 60 | 60 | 62 | 63 | 65 | 65 | 65 | 66 |
Humidification5* | Kg/h | 13 | 15 | 18 | 25 | 32 | |||||
Power | - | 3N-380V-50Hz | |||||||||
Input power | kw | 14.5 | 14.9 | 19.2 | 19.2 | 21.7 | 22.8 | 27.8 | 29.2 | 35.7 | 35.7 |
Compressor 6* | Type | Hermetic Scroll | |||||||||
Number | 2 | 2 | 2 | 2 | 2 | ||||||
Refrigerant | Type | R22/R407C/R410A | |||||||||
Manner | External balance type thermal expansion value/Electronic expansion value | ||||||||||
Strainer | - | Initial effect G4(Middle effect F8/Nanocrystalline carbon filter) | |||||||||
Drain pip | - | DN25 | DN25 | DN25 | DN25 | DN25 | |||||
Overall dimensions | Length(mm) | 2200 | 2600 | 2600 | 3200 | 3200 | |||||
Width(mm) | 1800 | 2200 | 2200 | 2200 | 2200 | ||||||
Height(mm) | 1520 | 1700 | 1700 | 1900 | 1900 | ||||||
Unit weight | kg | 780 | 780 | 810 | 810 | 850 | 850 | 1230 | 1230 | 1370 | 1370 |
1. Cooling condition: Indoor dry bulb/wet bulb: 35/28℃,Outdoor dry bulb/wet bulb: 27/19℃
2. Heating condition:Indoor dry bulb/wet bulb: 0/-2.9℃;outdoor dry bulb/wet bulb:20/15℃;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. The noise is measured at a height of 1.2m and 2m from the front of the unit when cooling under standard air volume;
5. Heaters, humidifiers, hot and cold water coils are optional parts, and specific forms can be configured according to customer site requirements;
6. The inverter compressor system can be used to achieve more precise capacity control;
7. The fresh air unit is limited to processing fresh air, indoor temperature control and main load bearing must be handled by standard air-conditioning equipment.
Application:
Such as hotel, office building, centralized air conditioning requirements of buildings, shopping malls, dance halls, theaters, hospitals, hydropower engineering, computer room and industrial and mining enterprises and other occasions.