Wheel Heat Recovery Type Rooftop Package Unit
Description:
1. Rooftop air conditioner generally have many functions such as refrigeration,heating,air supply,easy to use,low cost installation, low maintenance cost, widely used in air conditioning engineering project.
2. Rooftop air conditioner,saving the cooling tower and cooling water pump cost for customers, is particularly suitable for water shortage area.It does not need special room for installation, and can be installed on the roof or building ground outside
3. package unit heat pump is widely used in large space of centralized air treatment, such as convention and exhibition center,stadiums, theatres, shopping malls, supermarkets, waiting room, conference room, production workshop, library,etc.
4. It is equipped with high performance compressor,low noise axial flow fan, high precision grades of electronic expansion valve,and advanced control system.
Model:SL-WKR-()-HR | 30 | 50 | 60 | 70 | 90 | 100 | 110 | 130 | ||
Cooling capacity1* | kw | 31.8 | 49.6 | 63.6 | 75.5 | 88.1 | 100.5 | 109.5 | 130.9 | |
Heating capacity2* | kw | 30.7 | 49.3 | 63.0 | 74.5 | 85.2 | 99.5 | 105.7 | 127.0 | |
Wheel heat recovery efficiency | - | >=65% | ||||||||
Supply fan 3* | Supply Air | m3/h | 5500 | 8000 | 11000 | 13000 | 15000 | 17500 | 19500 | 23000 |
Static Pressure | Pa | 250 | 250 | 300 | 300 | 350 | 350 | 400 | 400 | |
Fan power | kw | 1.5 | 2.2 | 3.0 | 5.5 | 7.5 | 7.5 | 11.0 | 11.0 | |
Exhaust fan 3* | Fresh/Exhaust air | m3/h | 1100 | 1600 | 2200 | 2600 | 3000 | 3500 | 3900 | 4600 |
Static Pressure | Pa | 100 | 100 | 120 | 120 | 120 | 120 | 150 | 150 | |
Fan power | kw | 0.2 | 0.3 | 0.5 | 0.5 | 0.6 | 0.8 | 1.1 | 1.5 | |
Noise 4* | dB(A) | 65 | 68 | 69 | 69 | 70 | 70 | 71 | 72 | |
Temperature control | ℃ | 18~28 | ||||||||
Power | - | 3N-380V-50Hz | ||||||||
Input power | kw | 10.0 | 15.4 | 19.0 | 22.6 | 26.4 | 30.2 | 32.7 | 39.7 | |
Compressor 5* | Type | Hermetic Scroll | ||||||||
Number | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 4 | ||
Refrigerant | Type | R22/R407C/R410A | ||||||||
Manner | External balance type thermal expansion value/Electronic expansion value | |||||||||
Filter | - | Initial effect G4(Middle effect F8/Nanocrystalline carbon filter) | ||||||||
Drain pip | - | DN25 | DN25 | DN25 | DN25 | DN25 | DN25 | DN25 | DN40 | |
Overall dimensions | Length(mm) | 4800 | 5200 | 5500 | 5500 | 5500 | 5850 | 5850 | 5850 | |
Width(mm) | 1400 | 1800 | 2200 | 2200 | 2200 | 2200 | 2200 | 2300 | ||
Height(mm) | 1200 | 1520 | 1700 | 1700 | 1900 | 1900 | 1900 | 2805 | ||
Unit weight | kg | 700 | 970 | 1180 | 1400 | 1480 | 1620 | 1850 | 2050 |
1. Cooling condition: Indoor dry bulb/wet bulb: 35/24℃,Outdoor dry bulb/wet bulb: 27/19℃
2. Heating condition:Indoor dry bulb/wet bulb: 7/6℃;outdoor dry bulb/wet bulb:20/13.8℃;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. The inverter compressor system can be used to achieve more precise capacity control;
5. Heaters, humidifiers, hot and cold water coils are optional parts, and specific forms can be configured according to customer site requirements;
6. The noise is measured at a height of 1.2m and 2m directly in front of the unit when cooling under standard air volume;
7. The unit adopts a runner heat recovery device, and can be equipped with plate heat recovery and heat pipe heat recovery devices according to customer site requirements.
8. The fresh air unit is limited to processing fresh air, indoor temperature control and main load bearing must be handled by standard air conditioning equipment.
Application:
Residential, office building, shopping mall...