Constant Temperature And Humidity Rooftop Air Conditioner
Description:
1. Cooling capacity: 120kw to 360kw, a variety of choices.
2. High external pressure.
3. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.
Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
Model:SL-WKH | 120 | 150 | 180 | 200 | 230 | 260 | 330 | 360 | |
Cooling capacity 1* | kW | 120.0 | 142.0 | 178.0 | 203.0 | 230.0 | 265.0 | 325.0 | 362.0 |
Electric heating capacity 2* | kW | 48 | 54 | 72 | 72 | 90 | 90 | 90 | 90 |
Air volume 3* | m³/h | 22000 | 25500 | 33000 | 36000 | 40000 | 45000 | 50000 | 55000 |
External static pressure 3* | Pa | 450 | 450 | 550 | 550 | 550 | 600 | 650 | 650 |
Fan power 3* | kW | 15.0 | 15.0 | 18.5 | 18.5 | 18.5 | 22.0 | 22.0 | 30.0 |
Noise 4* | dB(A) | 72 | 75 | 75 | 76 | 76 | 77 | 80 | 80 |
Temperature control range | ℃ | 18~28±1 | |||||||
Humidity control range | % | 45~70±5 | |||||||
Supply power | - | 3N-380V-50Hz | |||||||
Input power | kW | 104.4 | 117.5 | 151.6 | 160.5 | 187.8 | 203.4 | 224.1 | 244.8 |
Compressor 5* | Type | Hermetic Scroll | |||||||
No. | 4 | 4 | 4 | 6 | 6 | 6 | 8 | 8 | |
Refrigerant | Type | R22/R407C/R410A | |||||||
Method | External balance type thermal expansion value/Electronic expansion value | ||||||||
Heater 6* | Type | Steam heating coil/hot water heating coil | |||||||
kW | 60 | 70 | 90 | 90 | 100 | 100 | 120 | 120 | |
Humidifier 6* | Type | Steam/wet film/electrode type | |||||||
kg/h | 3-18 | 3-18 | 8-45 | 8-45 | 8-45 | 8-45 | 8-45 | 8-45 | |
Filter | - | Initial effect G4(Middle effect F8/Nanocrystalline carbon filter) | |||||||
Drain pipe | - | DN40 | DN40 | DN40 | DN50 | DN50 | DN50 | DN50 | DN50 |
Overall dimensions | Length(mm) | 6500 | 6800 | 6800 | 7300 | 7300 | 7300 | 9600 | 9600 |
Width(mm) | 2300 | 2300 | 2300 | 2300 | 2300 | 2600 | 2600 | 2600 | |
Height(mm) | 2300 | 2300 | 2300 | 2500 | 2800 | 2800 | 2800 | 2800 | |
Unit weight | kg | 2530 | 2650 | 2880 | 3050 | 3260 | 3450 | 3820 | 3980 |
1. Cooling condition: Indoor dry bulb/wet bulb:27/19℃,Outdoor dry bulb/wet bulb:35/24℃
2. Heating condition:Indoor dry bulb/wet bulb:20/—℃;outdoor dry bulb/wet bulb:7/6℃;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Inverter compressor system can be used to achieve more precise capacity control;
6. The unit adopts a runner heat recovery device, which can be equipped with plate heat recovery and heat pipe heat recovery devices according to customer site requirements
Application:
![]() ![]() | ![]() ![]() |