Brand Name :Shenglin
Model Number :SLZK Series
Certification :CE
Place of Origin :China
MOQ :1
Price :5000~10020USD/unit
Payment Terms :T/T, Western Union
Supply Ability :100 Units Per Month
Delivery Time :35~40days
Packaging Details :Plywood wooden box or stretch film +pallet
AHU Type :Chilled water
Outdoor unit :Modular chiller unit
Mounting :Floor standing
Advantage A :Precise temperature control
Advantage B :Low ambient temperature refrigeration
Advantage C :Low ring temperature heating
Advantage D :Intelligent defrosting
Advantage E :Smart cloud service
Condition :Fresh air or fresh + return air condition
Keyword :Constant Temperature And Humidity Unit
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Constant Temperature And Humidity Air Handling Unit For Hospital Operating Room

Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room

According to the clean operating room design specifications, the clean air conditioning system must have core technical indicators such as constant temperature, constant humidity, fresh air treatment, air purification, and ensuring the positive and negative pressure difference in the controlled area to achieve the design requirements for controlling the concentration of bacteria and reducing the risk of infection. Clean air conditioners have multiple functions such as air purification, transportation, cooling, dehumidification, humidification, heating, heat recovery, and intelligent control, providing users with clean environment system solutions suitable for different purification levels and different working conditions.

AHU model representation method:

Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room

Unit quick selection table (air volume)

Model Nominal air volume m³/h Windward area of coil㎡ Wind speed of the coil(m/s)
2.00 2.25 2.50 2.75 3.00 3.25
m³/h
SLZK015W 1500 0.16 1152 1296 1440 1584 1728 1872
SLZK018W 1800 0.2 1440 1620 1800 1980 2160 2340
SLZK022W 2200 0.24 1728 1944 2160 2376 2592 2808
SLZK032W 3200 0.35 2520 2835 3150 3465 3780 4095
SLZK038W 3800 0.42 3024 3402 3780 4158 4536 4914
SLZK050W 5000 0.56 4032 4536 5040 5544 6048 6552
SLZK063W 6300 0.7 5040 5670 6300 6930 7560 8190
SLZK072W 7200 0.8 5760 6480 7200 7920 8640 9360
SLZK095W 9500 1.04 7488 8424 9360 10296 11232 12168
SLZK120W 12000 1.3 9360 10530 11700 12870 14040 15210
SLZK150W 15000 1.69 12168 13689 15210 16731 18252 19773
SLZK180W 18000 2.08 14976 16848 18720 20592 22464 24336
SLZK230W 23000 2.56 18432 20736 23040 25344 27648 29952
SLZK270W 27000 3.04 21888 24624 27360 30096 32832 35568
SLZK320W 32000 3.61 25992 29241 32490 35739 38988 42237
SLZK370W 37000 4.18 30096 33858 37620 41382 45144 48906
SLZK430W 43000 4.75 34200 38475 42750 47025 51300 55575
SLZK500W 50000 5.5 39600 44550 49500 54450 59400 64350
SLZK550W 55000 6.16 44352 49896 55440 60984 66528 72072
SLZK630W 63000 7 50400 56700 63000 69300 75600 81900
SLZK700W 70000 7.84 56448 63504 70560 77616 84672 91728
SLZK760W 76000 8.5 61200 68850 76500 84150 91800 99450
SLZK850W 85000 9.52 68544 77112 85680 94248 102816 111384
SLZK930W 93000 10.36 74592 83916 93240 102564 111888 121212
SLZK1000W 100000 11.47 82584 92907 103230 113553 123876 134199
SLZK1100W 110000 12.58 90576 101898 113220 124542 135864 147186

Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.

Unit quick selection table (cooling capacity of coil section under return air condition)

Model Nominal air volume m³/h 4 rows 6 rows 8 rows
Cooling capacity Water volume Cooling capacity Water volume Cooling capacity Water volume
kW m³/h kW m³/h kW m³/h
SLZK015W 1500 8.2 1.4 10.9 1.87 13.2 2.27
SLZK018W 1800 10.2 1.8 13.6 2.34 16.5 2.84
SLZK022W 2200 12.6 2.2 16.4 2.82 19.8 3.41
SLZK032W 3200 17.8 3.1 23.8 4.09 28.8 4.95
SLZK038W 3800 21.5 3.7 28.6 4.92 34.6 5.95
SLZK050W 5000 28.7 4.9 38.1 6.55 46.2 7.95
SLZK063W 6300 35.8 6.2 47.8 8.22 57.5 9.89
SLZK072W 7200 41.1 7.1 54.6 9.39 66.1 11.37
SLZK095W 9500 53.3 9.2 70.8 12.18 85.6 14.72
SLZK120W 12000 66.7 11.5 88.6 15.24 107.1 18.42
SLZK150W 15000 86.6 14.9 115.3 19.83 138.6 23.84
SLZK180W 18000 106.5 18.3 141.8 24.39 170.3 29.29
SLZK230W 23000 131.2 22.6 172.9 29.74 210.5 36.21
SLZK270W 27000 155.8 26.8 206.8 35.57 248.6 42.76
SLZK320W 32000 185.1 31.8 245.2 42.17 296.5 51.00
SLZK370W 37000 214.2 36.8 285.1 49.04 341.8 58.79
SLZK430W 43000 243.3 41.8 323.6 55.66 385.6 66.32
SLZK500W 50000 281.5 48.4 374.5 64.41 450.3 77.45
SLZK550W 55000 315.7 54.3 419.3 72.12 500.4 86.07
SLZK630W 63000 358.6 61.7 476.5 81.96 560.4 96.39
SLZK700W 70000 400.5 68.9 534.1 91.87 640.5 110.17
SLZK760W 76000 432.6 74.4 578.2 99.45 690.5 118.77
SLZK850W 85000 482.5 83.0 645.8 111.08 765.8 131.72
SLZK930W 93000 520.6 89.5 702.3 120.80 830.5 142.85
SLZK1000W 100000 576.1 99.1 778.4 133.88 940.8 161.82
SLZK1100W 110000 630.6 108.5 850.6 146.30 970.5 166.93

Note:

1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;

2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;

3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(parameter table of DX outdoor unit of clean room air conditioning unit)

Model SRF8W SRF13W SRF18W SRF21W SRF24W SRF30W SRF36W SRF39W SRF45W SRF51W SRF54W SRF60W SRF72W SRF90W SRF105W SRF225W SRF300W
Cooling capacity kW 7.5 12.8 17.6 20.5 24 30.6 36.3 38.6 44.7 51.2 54.3 61.8 72.8 89.4 105.3 225 300
Heating capacity kW 8.1 13.9 19.1 22.3 26.1 33.5 39.7 41.5 48.9 56.3 59.6 68.2 80 97.8 115.1 245 326
Input power kW 2.7 4.3 5.4 6.4 7.3 9.3 11 11.6 13.5 15.6 16.3 18 22 27.8 32.9 70.2 93.5
Supply power 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz 3Ph 380V 50Hz
Energy control 0,100% 0,100% 0,100% 0,100% 0,100% 0,100% 0,100% 0,100% 0,100% 0,30%,70%,100% 0,33%,66%,100% 0,50%,100% 0,50%,100% 0,50%,100% 0,33%,66%,100% 0,33%,66%,100% 0,25%,50%,75%,100%
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Compressor Type Scroll compressor
Qty 1 1 1 1 1 1 1 1 1 2 2 2 2 2 3 3 4
Fan Type Axial fan
Air volume m³/h 5500 5500 8000 8000 9000 12000 14000 15200 17000 20000 20000 22000 2x13000 2x17000 2x19000 2x15000+2x26000 4x26000
Power kW 0.20 0.25 0.37 0.37 0.55 0.75 0.75 1.10 1.10 1.50 1.50 1.80 2x0.75 2x1.5 2x1.5 2x0.75+2x2.2 4x2.2
Qty 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 4 4
Condenser Copper tube and aluminum fin
Connecting pipe of indoor and outdoor unit Liquid pipe Type φ9.52x1 φ12.7x1 φ12.7x1 φ12.7x1 φ16x1 φ16x1 φ16x1 φ16x1 φ19x1 φ12.7x1+φ16x1 φ12.7x1+φ16x1 φ16x1 φ16x1 φ19x1 φ16x1 φ22x1 φ22x1
Qty 1 1 1 1 1 1 1 1 1 2 2 2 2 2 3 3 4
Gas pipe Type φ16x1.0 φ19x1.0 φ19x1.0 φ19x1.0 φ28x1.2 φ28x1.2 φ28x1.2 φ28x1.2 φ35x1.5 φ19x1+φ28x1.2 φ22x1+φ28x1.2 φ28x1.2 φ28x1.2 φ35x1.5 φ28x1.2 φ35x1.5 φ35x1.5
Qty 1 1 1 1 1 1 1 1 1 2 2 2 2 2 3 3 4
Dimension L mm 930 910 800 800 930 960 960 1060 1060 1350 1350 1350 1950 2250 2250 2396 2396
W mm 370 400 860 860 820 1020 1020 1090 1090 1060 1060 1060 1100 1250 1250 2260 2260
H mm 700 1335 1115 1115 1115 1115 1115 1240 1240 1240 1240 1495 1440 1500 1500 2454 2454
Weight kg 65 96 124 130 154 175 180 225 232 254 263 318 350 450 510 1100 1420

Note:

1. The above models are for reference only, and different working conditions will lead to different parameters;

2. Compressor frequency conversion series can be customized according to non-standard;

Note:

1. Cooling capacity calibration working condition: ambient temperature 35℃, inlet air temperature 27/19℃;

2. Heating capacity calibration working conditions: ambient dry and wet bulb temperature 7/6℃, inlet air temperature 20℃;

3. The above parameters are for reference only. If the working conditions are changed, the parameters will be changed.

Reference:

Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room

China Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room for sale

Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room

Inquiry Cart 0